# Water quality in Brookville, NY (Nassau County)

- Water source: Public water
- Supplier / district: Jericho Water District
- Supplier contact: Jericho Water District (https://www.jerichowater.org/wp-content/uploads/2026/05/JWD_2025_ADWQR.pdf)
- Report year: 2025 · Verified: 2026-11-11
- Web page: https://www.fieldstonewater.com/water/brookville
- JSON: https://www.fieldstonewater.com/api/v1/towns/brookville

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. The report carries 2 notices: No MCL violations reported ('our system did not violate a maximum contaminant level or any other water quality standard', page 1). Page 5 narrative ('Is our water system meeting other rules that govern operations?'): NYSDOH issued a deferral on November 24th, 2020 for MCL compliance for 1,4-Dioxane, which was found in the District drinking water above its New York State MCL of 1 ug/L during 2020. Deferral effective until August 25th, 2022; renewed July 2022 (to August 25th, 2023); in August 2023 the District was granted an exemption from the 1,4-Dioxane MCL (to August 25th, 2024); the District requested a second 12-month exemption to extend its MCL compliance deadline to August 2025. AOP treatment facilities at seven wells are being constructed; quarterly updates at www.jerichowater.org/deferralquarterlyreport. Nitrate advisory (page 2): 'Although nitrate was detected below the MCL, it was detected at 6.4 which is greater than one-half of the MCL', so the report includes the required nitrate/blue-baby-syndrome information. 100% of Brookville's land lies inside a public water service area (Jericho Water District), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

## Summary

No contaminant averaged above its limit in the reported year.
Individual samples above the limit: Lead (high 33.3 vs limit 15 µg/L).
Detected: Barium, Bromide, Calcium, Chloride, Iron, Magnesium, Nickel, Sodium, Sulfate, Zinc, Nitrate, Nitrite, Nitrate-Nitrite (as N), Calcium hardness, Corrosivity (LSI), Odor, pH, Specific conductance, Alkalinity, Total Dissolved Solids, Hardness (total), Free Chlorine, 1,1-Dichloroethene, 1,2-Dichloropropane, 1,2,3-Trichloropropane, Chlorodifluoromethane, Tetrachloroethene (PCE), Trichloroethene (TCE), 1,1-Dichloroethane, Total Trihalomethanes, 1,4-Dioxane, PFOA, Simazine, Bromodichloromethane, Chloroform, Dibromochloromethane, Gross alpha, Gross beta, Combined Radium 226/228, Uranium, Strontium, Copper, Lead, Acetaldehyde, Formaldehyde, Glyoxal, Methyl glyoxal, Perchlorate, 6:2 FTS, PFBS, PFBA, PFHpA, PFHxA, PFPeA.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Barium | 0.013 | ND to 0.013 | mg/L | 2 | EPA MCL | detected | no | — |
| Bromide | 0.14 | 0.14 to 0.14 | mg/L | — | No regulatory limit | detected | no | — |
| Calcium | 15.8 | 1.2 to 15.8 | mg/L | — | No regulatory limit | detected | no | — |
| Chloride | 40.9 | 3.9 to 40.9 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Iron | 45 | ND to 45 | µg/L | 300 | NYS secondary standard | detected | no | — |
| Magnesium | 6.4 | 0.51 to 6.4 | mg/L | — | No regulatory limit | detected | no | — |
| Nickel | 0.0037 | ND to 0.0037 | mg/L | — | No regulatory limit | detected | no | — |
| Sodium | 25 | 3.5 to 25 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Sulfate | 18.4 | ND to 18.4 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Zinc | 0.21 | ND to 0.21 | mg/L | 5 | NYS secondary standard | detected | no | — |
| Nitrate | 36.7 | 3 to 36.7 | mg/L | 10 | EPA MCL | detected | no | — |
| Nitrite | 0.054 | ND to 0.054 | mg/L | 1 | EPA MCL | detected | no | — |
| Nitrate-Nitrite (as N) | 6.4 | 0.13 to 6.4 | mg/L | 10 | EPA MCL | detected | no | — |
| Calcium hardness | -1.17 | -5.14 to -1.17 | mg/L | — | No regulatory limit | detected | no | — |
| Corrosivity (LSI) | -1.05 | -5.06 to -1.05 | — | — | No regulatory limit | detected | no | — |
| Odor | 1 | ND to 1 | Units | 3 | NYS secondary standard | detected | no | — |
| pH | 7.1 | 5.3 to 7.1 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Specific conductance | 278 | 81.9 to 278 | umhos/cm | — | No regulatory limit | detected | no | — |
| Alkalinity | 67.7 | ND to 67.7 | mg/L | — | No regulatory limit | detected | no | — |
| Total Dissolved Solids | 128 | ND to 128 | mg/L | — | No regulatory limit | detected | no | — |
| Hardness (total) | 55.4 | 5.9 to 55.4 | mg/L | — | No regulatory limit | detected | no | — |
| Free Chlorine | 1.1 | 0 to 1.1 | mg/L | 4 | EPA MRDL | detected | no | — |
| 1,1-Dichloroethene | 0.54 | ND to 0.54 | µg/L | 5 | EPA MCL | detected | no | — |
| 1,2-Dichloropropane | 2.8 | ND to 2.8 | µg/L | 5 | EPA MCL | detected | no | — |
| 1,2,3-Trichloropropane | 0.71 | ND to 0.71 | µg/L | 5 | EPA MCL | detected | no | — |
| Chlorodifluoromethane | 4.2 | ND to 4.2 | µg/L | 5 | EPA MCL | detected | no | — |
| Tetrachloroethene (PCE) | 0.62 | ND to 0.62 | µg/L | 5 | EPA MCL | detected | no | — |
| Trichloroethene (TCE) | 1.7 | ND to 1.7 | µg/L | 5 | EPA MCL | detected | no | — |
| 1,1-Dichloroethane | 1.5 | ND to 1.5 | µg/L | 5 | EPA MCL | detected | no | — |
| Total Trihalomethanes | 2.1 | ND to 2.1 | µg/L | 80 | EPA MCL | detected | no | — |
| 1,4-Dioxane | 0.78 | ND to 0.78 | µg/L | 1 | NYS MCL | detected | no | — |
| PFOA | 3.14 | ND to 3.14 | ng/L | 10 | NYS MCL | detected | no | — |
| Simazine | 0.11 | ND to 0.11 | µg/L | 4 | EPA MCL | detected | no | — |
| Bromodichloromethane | 0.75 | ND to 0.75 | µg/L | 80 | EPA MCL | detected | no | — |
| Chloroform | 0.71 | ND to 0.71 | µg/L | 80 | EPA MCL | detected | no | — |
| Dibromochloromethane | 0.76 | ND to 0.76 | µg/L | 80 | EPA MCL | detected | no | — |
| Gross alpha | 0.667 | -0.937 to 0.667 | pCi/L | 15 | EPA MCL | detected | no | — |
| Gross beta | 3.87 | 0.008 to 3.87 | pCi/L | 50 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 3.17 | 0.281 to 3.17 | pCi/L | 5 | EPA MCL | detected | no | — |
| Uranium | 0.3335 | -0.008 to 0.3335 | µg/L | 30 | EPA MCL | detected | no | — |
| Strontium | 66.1 | 66.1 to 66.1 | µg/L | 4000 | EPA health advisory | detected | no | — |
| Copper | 0.23 | ND to 1.1 | mg/L | 1.3 | EPA action level | detected | no | — |
| Lead | 1.7 | ND to 33.3 | µg/L | 15 | EPA action level | detected | yes | — |
| Acetaldehyde | 5.8 | ND to 5.8 | µg/L | — | No regulatory limit | detected | no | — |
| Formaldehyde | 17.3 | ND to 17.3 | µg/L | — | No regulatory limit | detected | no | — |
| Glyoxal | 84.3 | ND to 84.3 | µg/L | — | No regulatory limit | detected | no | — |
| Methyl glyoxal | 14.2 | ND to 14.2 | µg/L | — | No regulatory limit | detected | no | — |
| Perchlorate | 4.9 | ND to 4.9 | pCi/L | 18 | NYS MCL | detected | no | — |
| 6:2 FTS | 7.16 | ND to 7.16 | ng/L | — | No regulatory limit | detected | no | — |
| PFBS | 1.9 | ND to 1.9 | ng/L | — | No regulatory limit | detected | no | — |
| PFBA | 33 | ND to 33 | ng/L | — | No regulatory limit | detected | no | — |
| PFHpA | 6.18 | ND to 6.18 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxA | 16.2 | ND to 16.2 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 26.6 | ND to 26.6 | ng/L | — | No regulatory limit | detected | no | — |
| HFPO-DA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 31 |
| PFOS | — | ND to ND | µg/L | 0.01 | NYS MCL | not-detected | no | 31 |
| PFNA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 31 |
| PFHxS | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 31 |

## Sources

- Jericho Water District 2025 Annual Water Quality Report: https://www.jerichowater.org/wp-content/uploads/2026/05/JWD_2025_ADWQR.pdf
- EPA UCMR 5 PFAS results, 2023–2025 (entry-point samples): https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Liberty Utilities New York - Sea Cliff | NY2902853 | 0 | 0 | 0 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902853 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For Brookville, the numbers point first to under-sink reverse osmosis and whole-house carbon filtration: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 36.7 mg/L with samples up to 36.7 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. PFOA/PFOS reached 3.14 ng/L (ppt) in at least one sample — under New York's 10 ppt limit. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 25 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 4.9 µg/L (limit 18). The supplier's 90th-percentile lead result was 0.0017 mg/L (2 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.
- **Whole-House Carbon Filtration** (recommended): Solvent traces and chlorine in the supply. Free chlorine averaged 1.1 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 0.75 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk. Solvent traces were detected: Trichloroethene (TCE) up to 1.7 µg/L, Tetrachloroethene (PCE) up to 0.62 µg/L (limit 5 each). Whether a whole-house carbon model reduces those solvents is on that model's data sheet.
- **Whole-House + Softener Combo** (not needed): Hardness 55.4 mg/L, about 3.2 grains per gallon. At 55.4 mg/L (3.2 gpg) the water is soft. A softener is not needed.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/brookville, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license