Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. Water Authority of Great Neck North's report does not name Great Neck Gardens in its service area. The service-area boundary the NYS Department of Health supplies to EPA places most of Great Neck Gardens inside the district (https://www.epa.gov/ground-water-and-drinking-water/community-water-system-service-area-boundaries). That mapping is not in the report. 100% of Great Neck Gardens's land lies inside a public water service area (Water Authority of Great Neck North), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

## Summary

No contaminant averaged above its limit in the reported year.
Individual samples above the limit: Toluene (high 14.10 vs limit 5 µg/L); Lead (high 20.2 vs limit 15 µg/L).
Detected: Barium, Calcium, Chloride, Copper, Iron, Magnesium, Manganese, Nickel, Perchlorate, Sodium, Sulfate, Zinc, Nitrate, Bromodichloromethane, Bromoform, Chloroform, Dibromochloromethane, Toluene, Dacthal (DCPA), Hexavalent Chromium, 1,4-Dioxane, PFOA, Copper, Lead, Bromide, Chlorate, Gross alpha, Gross beta, Combined Radium 226/228, Uranium, Alkalinity, Calcium hardness, pH, Total Dissolved Solids, Hardness (total), Turbidity, PFBA, PFHxA, PFPeA.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Barium | 0.056 | 0.0047 to 0.056 | mg/L | 2 | EPA MCL | detected | no | — |
| Calcium | 37.6 | 11.0 to 37.6 | mg/L | — | No regulatory limit | detected | no | — |
| Chloride | 121 | 10.0 to 121 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Copper | 0.042 | ND to 0.042 | mg/L | 1.3 | EPA action level | detected | no | — |
| Iron | 83 | ND to 83 | µg/L | 300 | NYS secondary standard | detected | no | — |
| Magnesium | 20.7 | 0 to 20.7 | mg/L | — | No regulatory limit | detected | no | — |
| Manganese | 28 | ND to 28 | µg/L | 300 | NYS secondary standard | detected | no | — |
| Nickel | 0.0016 | ND to 0.0016 | mg/L | — | No regulatory limit | detected | no | — |
| Perchlorate | 6.1 | ND to 6.1 | mg/L | 18 | EPA action level | detected | no | — |
| Sodium | 34.4 | 6.5 to 34.4 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Sulfate | 51.3 | 10.3 to 51.3 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Zinc | 0.023 | ND to 0.023 | mg/L | 5 | NYS secondary standard | detected | no | — |
| Nitrate | 4.1 | 0 to 4.1 | mg/L | 10 | EPA MCL | detected | no | — |
| Bromodichloromethane | 3.7 | ND to 3.7 | µg/L | — | No regulatory limit | detected | no | — |
| Bromoform | 3.2 | ND to 3.2 | µg/L | — | No regulatory limit | detected | no | — |
| Chloroform | 10.4 | ND to 10.4 | µg/L | — | No regulatory limit | detected | no | — |
| Dibromochloromethane | 1.90 | ND to 1.90 | µg/L | — | No regulatory limit | detected | no | — |
| Toluene | 3.6 | ND to 14.10 | µg/L | 5 | EPA MCL | detected | yes | — |
| Dacthal (DCPA) | 5.8 | ND to 5.8 | µg/L | 50 | EPA MCL | detected | no | — |
| Hexavalent Chromium | 0.57 | ND to 0.57 | µg/L | 50 | EPA MCL | detected | no | — |
| 1,4-Dioxane | 0.23 | ND to 0.23 | µg/L | 1.0 | NYS MCL | detected | no | — |
| PFOA | 4.61 | ND to 4.61 | ng/L | 10.0 | NYS MCL | detected | no | — |
| Copper | 0.19 | ND to 0.35 | mg/L | 1.3 | EPA action level | detected | no | — |
| Lead | 2.8 | ND to 20.2 | µg/L | 15 | EPA action level | detected | yes | — |
| Bromide | 0.3 | ND to 0.3 | mg/L | — | No regulatory limit | detected | no | — |
| Chlorate | 38.7 | ND to 38.7 | µg/L | — | No regulatory limit | detected | no | — |
| Gross alpha | 1.41 | ND to 1.41 | (pCi/L) | 15.0 | EPA MCL | detected | no | — |
| Gross beta | 2.25 | 0.297 to 2.25 | (pCi/L) | 16.0 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 1.46 | ND to 1.46 | (pCi/L) | 5.0 | EPA MCL | detected | no | — |
| Uranium | 0.71 | ND to 0.71 | µg/L | 30.0 | EPA MCL | detected | no | — |
| Alkalinity | 81.0 | 31.0 to 81.0 | mg/L | — | No regulatory limit | detected | no | — |
| Calcium hardness | 93.9 | 27.5 to 93.9 | mg/L | — | No regulatory limit | detected | no | — |
| pH | 8.0 | 7.2 to 8.0 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Total Dissolved Solids | 279 | 98 to 179 | mg/L | — | No regulatory limit | detected | no | — |
| Hardness (total) | 179 | 59.3 to 179 | mg/L | — | No regulatory limit | detected | no | — |
| Turbidity | 2.3 | ND to 2.3 | NTU | 5 | EPA MCL | detected | no | — |
| PFBA | 4.12 | ND to 4.12 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxA | 3.14 | ND to 3.14 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 6.46 | ND to 6.46 | ng/L | — | No regulatory limit | detected | no | — |

## Sources

- Water Authority of Great Neck North 2025 Annual Water Quality Report: https://www.waterauthorityofgreatnecknorth.com/pdf/2025%20AWQR%20FINAL%20for%20website.pdf

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Manhasset Lakeville Water District | NY2902836 | 0 | 0 | 0 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902836 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For Great Neck Gardens, the numbers point first to under-sink reverse osmosis and whole-house + softener combo: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 4.1 mg/L (limit 10), moderate but present; reverse osmosis reduces it at the tap. PFOA/PFOS reached 4.61 ng/L (ppt) in at least one sample — under New York's 10 ppt limit but at or above the 4.0 ppt federal MCL, with federal compliance due April 26, 2029. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 34.4 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 6.1 µg/L (limit 18). The supplier's 90th-percentile lead result was 0.0028 mg/L (3 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.
- **Whole-House + Softener Combo** (recommended): Hardness 179 mg/L, about 10.5 grains per gallon. At 179 mg/L (10.5 gpg) this is hard water: it scales water heaters, spots glassware and leaves film on skin. A softener paired with carbon is the standard fix above 7 grains.
- **Whole-House Carbon Filtration** (worth considering): Chlorine and taste at every tap. Chlorination by-products (trihalomethanes) reached 10.4 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/great-neck-gardens, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license