# Water quality in Hicksville, NY (Nassau County)

- Water source: Public water
- Supplier / district: Hicksville Water District
- Supplier contact: Hicksville Water District (https://hicksvillewater.org/wp-content/uploads/2026/05/26.04.28-2025-HKWD-Drinking-Water-Quality-Report-FINAL1.pdf)
- Report year: 2025 · Verified: 2026-11-11
- Web page: https://www.fieldstonewater.com/water/hicksville
- JSON: https://www.fieldstonewater.com/api/v1/towns/hicksville

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. The report carries 1 notice: No violations reported: 'We are pleased to report that our drinking water meets all Federal and State requirements.' (page 2). All table rows print Violation 'No'. Footnote (4) notes one sample exceeded the 15 color unit standard for apparent color (aesthetic parameter). 100% of Hicksville's land lies inside a public water service area (Hicksville Water District and others), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

## Summary

Reported above a limit: Color.
Detected: Copper, Barium, Calcium, Chloride, Sodium, Iron, Magnesium, Nickel, Sulfate, Bromide, Nitrate, Odor, Perchlorate, Selenium, Turbidity, Zinc, Chlorate, Dichlorodifluoromethane, Gross alpha, Gross beta, Combined Radium 226/228, Uranium, Free Chlorine, pH, Alkalinity, Calcium hardness, Hardness (total), Total Dissolved Solids, 1,4-Dioxane, Formic Acid, Acetic Acid, 6:2 FTS, PFBA, PFPeA, Hexavalent Chromium.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Copper | 0.076 | 0.0053 to 0.36 | mg/L | 1.3 | EPA action level | detected | no | — |
| Lead | ND | ND to 6.7 | µg/L | 15 | EPA action level | not-detected | no | — |
| Barium | 0.02 | 0.0025 to 0.02 | mg/L | 2 | EPA MCL | detected | no | — |
| Calcium | 17.2 | 5.1 to 17.2 | mg/L | — | No regulatory limit | detected | no | — |
| Chloride | 75.4 | 11.5 to 75.4 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Sodium | 40.5 | 7.5 to 40.5 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Iron | 0.17 | ND to 0.17 | mg/L | 0.3 | NYS secondary standard | detected | no | — |
| Magnesium | 5.9 | 2.1 to 5.9 | mg/L | — | No regulatory limit | detected | no | — |
| Nickel | 0.0051 | 0.00098 to 0.0051 | mg/L | — | No regulatory limit | detected | no | — |
| Sulfate | 22.3 | ND to 22.3 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Bromide | 0.080 | 0.054 to 0.080 | mg/L | — | No regulatory limit | detected | no | — |
| Color | 30.0 | ND to 30.0 | Units | 15 | NYS secondary standard | exceeds | yes | — |
| Nitrate | 8.3 | ND to 8.3 | mg/L | 10 | EPA MCL | detected | no | — |
| Odor | 1.0 | ND to 1.0 | Units | 3 | NYS secondary standard | detected | no | — |
| Perchlorate | 10.7 | ND to 10.7 | µg/L | 18 | EPA action level | detected | no | — |
| Selenium | 2.1 | ND to 2.1 | µg/L | 50 | EPA MCL | detected | no | — |
| Turbidity | 2.0 | ND to 2.0 | NTU | 5 | EPA MCL | detected | no | — |
| Zinc | 0.054 | ND to 0.054 | mg/L | — | No regulatory limit | detected | no | — |
| Chlorate | 21.0 | ND to 21.0 | µg/L | — | No regulatory limit | detected | no | — |
| Dichlorodifluoromethane | 0.86 | ND to 0.86 | µg/L | 5 | EPA MCL | detected | no | — |
| Gross alpha | 4.17 | -0.33 to 4.17 | pCi/L | 15 | EPA MCL | detected | no | — |
| Gross beta | 3.64 | 0.8 to 3.64 | pCi/L | 50 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 3.85 | 0.43 to 3.85 | pCi/L | 5 | EPA MCL | detected | no | — |
| Uranium | 0.16 | 0.03 to 0.16 | µg/L | 30 | EPA MCL | detected | no | — |
| Free Chlorine | 0.95 | 0.33 to 0.95 | mg/L | 4.0 | EPA MRDL | detected | no | — |
| pH | 8.2 | 7.6 to 8.2 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Alkalinity | 44.2 | 1.4 to 44.2 | mg/L | — | No regulatory limit | detected | no | — |
| Calcium hardness | 42.9 | 12.7 to 42.9 | mg/L | — | No regulatory limit | detected | no | — |
| Hardness (total) | 67.4 | 22.6 to 67.4 | mg/L | — | No regulatory limit | detected | no | — |
| Total Dissolved Solids | 197.0 | 65.0 to 197.0 | mg/L | — | No regulatory limit | detected | no | — |
| 1,4-Dioxane | 0.28 | ND to 0.28 | µg/L | 1.0 | NYS MCL | detected | no | — |
| Formic Acid | 10.0 | ND to 10.0 | µg/L | 50 | EPA MCL | detected | no | — |
| Acetic Acid | 28.0 | ND to 28.0 | µg/L | 50 | EPA MCL | detected | no | — |
| 6:2 FTS | 2.88 | ND to 2.88 | ng/L | — | No regulatory limit | detected | no | — |
| PFBA | 10.3 | ND to 10.3 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 7.2 | ND to 7.2 | ng/L | — | No regulatory limit | detected | no | — |
| Hexavalent Chromium | 0.99 | ND to 0.99 | µg/L | — | No regulatory limit | detected | no | — |
| PFOS | — | ND to ND | µg/L | 0.01 | NYS MCL | not-detected | no | 16 |
| PFOA | — | ND to ND | µg/L | 0.01 | NYS MCL | not-detected | no | 16 |
| PFNA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 16 |
| PFHxS | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 16 |
| PFBS | — | ND to ND | µg/L | — | No regulatory limit | not-detected | no | 16 |
| HFPO-DA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 16 |

## Sources

- Hicksville Water District 2025 Annual Water Quality Report: https://hicksvillewater.org/wp-content/uploads/2026/05/26.04.28-2025-HKWD-Drinking-Water-Quality-Report-FINAL1.pdf
- EPA UCMR 5 PFAS results, 2023–2025 (entry-point samples): https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Hicksville Water District | NY2902829 | 0 | 0 | 0 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902829 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For Hicksville, the numbers point first to under-sink reverse osmosis and whole-house carbon filtration: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 8.3 mg/L with samples up to 8.3 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. Sodium averaged 40.5 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 10.7 µg/L (limit 18).
- **Whole-House Carbon Filtration** (recommended): Chlorine residual 0.95 mg/L. Free chlorine averaged 0.95 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair.
- **Whole-House + Softener Combo** (worth considering): Hardness 67.4 mg/L, about 3.9 grains per gallon. At 67.4 mg/L (3.9 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/hicksville, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license