# Water quality in Mill Neck, NY (Nassau County)

- Water source: Public water, some private wells
- Supplier / district: Locust Valley Water District
- Supplier contact: Locust Valley Water District (https://locustvalleywater.com/wp-content/uploads/2026/04/2025-Annual-Water-Quality-Report.pdf)
- Report year: 2025 · Verified: 2026-11-11
- Web page: https://www.fieldstonewater.com/water/mill-neck
- JSON: https://www.fieldstonewater.com/api/v1/towns/mill-neck

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. The report carries 1 notice: No violations reported. Page 2: 'As you can see by the table, our system had no violations.' Page 1: 2025 Sanitary Survey by Nassau County Department of Health found 'full compliance of all regulations, without any deficiencies or violations.' Every Violation cell on page 3 is printed 'No'. About 63% of Mill Neck's land lies inside a public water service area (Locust Valley Water District and others), per the NYS Department of Health boundaries EPA publishes; the rest is on private wells. These results apply only to public water.

## Summary

No contaminant averaged above its limit in the reported year.
Detected: Copper, Barium, Zinc, Sodium, Chloride, Nitrate, Sulfate, Calcium hardness, Calcium, Nickel, Odor, Magnesium, Perchlorate, Gross alpha, Gross beta, Combined Radium 226/228, Uranium, 1,1-Dichloroethane, cis-1,2-Dichloroethene, Trichloroethene (TCE), Total Trihalomethanes, Haloacetic Acids (Total), 1,4-Dioxane, PFOA, Hexavalent Chromium, Alkalinity, Hardness (total), Total Dissolved Solids, Turbidity, pH, Free Chlorine, PFBA, PFNA, PFHxS.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Copper | 0.31 | 0.021 to 0.35 | mg/L | 1.3 | EPA action level | detected | no | — |
| Lead | ND | ND to 3.2 | µg/L | 15 | EPA action level | not-detected | no | — |
| Barium | 0.099 | 0.018 to 0.099 | mg/L | 2.0 | EPA MCL | detected | no | — |
| Zinc | 0.043 | ND to 0.043 | mg/L | 5.0 | NYS secondary standard | detected | no | — |
| Sodium | 39.5 | 7.5 to 39.5 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Chloride | 37.6 | 10.4 to 37.6 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Nitrate | 4.8 | 1.8 to 4.8 | mg/L | 10 | EPA MCL | detected | no | — |
| Sulfate | 27.3 | 8.4 to 27.3 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Calcium hardness | 55.70 | 20.4 to 55.70 | mg/L | — | No regulatory limit | detected | no | — |
| Calcium | 22.3 | 8.2 to 22.3 | mg/L | — | No regulatory limit | detected | no | — |
| Nickel | 0.001 | ND to 0.001 | mg/L | — | No regulatory limit | detected | no | — |
| Odor | 1 | ND to 1 | Units | 3 | NYS secondary standard | detected | no | — |
| Magnesium | 8.7 | 3.0 to 8.7 | mg/L | — | No regulatory limit | detected | no | — |
| Perchlorate | 9.1 | ND to 9.1 | µg/L | 18 | EPA action level | detected | no | — |
| Gross alpha | 0.260 | ND to 0.260 | pCi/L | 15 | EPA MCL | detected | no | — |
| Gross beta | 2.29 | 0.268 to 2.29 | pCi/L | 4 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 1.24 | 0.357 to 1.24 | pCi/L | 5 | EPA MCL | detected | no | — |
| Uranium | 0.130 | ND to 0.130 | µg/L | 30 | EPA MCL | detected | no | — |
| 1,1-Dichloroethane | 0.77 | ND to 0.77 | µg/L | 5 | EPA MCL | detected | no | — |
| cis-1,2-Dichloroethene | 1.8 | ND to 1.8 | µg/L | 5 | EPA MCL | detected | no | — |
| Trichloroethene (TCE) | 0.55 | ND to 0.55 | µg/L | 5 | EPA MCL | detected | no | — |
| Total Trihalomethanes | 7.4 | ND to 7.4 | µg/L | 80 | EPA MCL | detected | no | — |
| Haloacetic Acids (Total) | 2.6 | — | µg/L | 60 | EPA MCL | detected | no | — |
| 1,4-Dioxane | 0.20 | 0.045 to 0.20 | µg/L | 1.0 | NYS MCL | detected | no | — |
| PFOA | 4.34 | ND to 4.34 | ng/L | 10 | NYS MCL | detected | no | — |
| Hexavalent Chromium | 2.0 | 0.54 to 2.0 | µg/L | — | No regulatory limit | detected | no | — |
| Alkalinity | 79.5 | 15.4 to 79.5 | mg/L | — | No regulatory limit | detected | no | — |
| Hardness (total) | 91.6 | 34.0 to 91.6 | mg/L | — | No regulatory limit | detected | no | — |
| Total Dissolved Solids | 191 | 71 to 191 | mg/L | — | No regulatory limit | detected | no | — |
| Turbidity | 1.0 | ND to 1.0 | NTU | 5 | EPA MCL | detected | no | — |
| pH | 8.2 | 7.0 to 8.2 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Free Chlorine | 0.97 | 0.5 to 0.97 | mg/L | 4.0 | EPA MRDL | detected | no | — |
| PFBA | 2.06 | ND to 2.06 | ng/L | — | No regulatory limit | detected | no | — |
| PFNA | 2.42 | ND to 2.42 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxS | — | ND to 0.0045 | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | detected | no | 10 |
| HFPO-DA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 10 |
| PFOS | — | ND to ND | µg/L | 0.01 | NYS MCL | not-detected | no | 10 |
| PFBS | — | ND to ND | µg/L | — | No regulatory limit | not-detected | no | 10 |

## Sources

- Locust Valley Water District 2025 Annual Water Quality Report: https://locustvalleywater.com/wp-content/uploads/2026/04/2025-Annual-Water-Quality-Report.pdf
- EPA UCMR 5 PFAS results, 2023–2025 (entry-point samples): https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For Mill Neck, the numbers point first to under-sink reverse osmosis and whole-house carbon filtration: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 4.8 mg/L (limit 10), moderate but present; reverse osmosis reduces it at the tap. PFOA/PFOS reached 4.34 ng/L (ppt) in at least one sample — under New York's 10 ppt limit but at or above the 4.0 ppt federal MCL, with federal compliance due April 26, 2029. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 39.5 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 9.1 µg/L (limit 18). Hexavalent chromium averaged 2 µg/L; there is no federal limit for chromium-6 itself, and reverse osmosis reduces it.
- **Whole-House Carbon Filtration** (recommended): Solvent traces and chlorine in the supply. Free chlorine averaged 0.97 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Solvent traces were detected: Trichloroethene (TCE) up to 0.55 µg/L, cis-1,2-Dichloroethene up to 1.8 µg/L (limit 5 each). Whether a whole-house carbon model reduces those solvents is on that model's data sheet.
- **Whole-House + Softener Combo** (worth considering): Hardness 91.6 mg/L, about 5.4 grains per gallon. At 91.6 mg/L (5.4 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity.
- **Private Well Treatment** (worth considering): Private wells in part of the community. Part of Mill Neck is on private wells that none of these figures cover; a well needs its own test, and a well package is sized to what it finds.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/mill-neck, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license