# Water quality in North Valley Stream, NY (Nassau County)

- Water source: Public water
- Supplier / district: Water Authority of Western Nassau County
- Supplier contact: Water Authority of Western Nassau County (https://www.gardencityny.net/DocumentCenter/View/4147/2026-Water-Authority-of-Western-Nassau-County-Water-Quality-Report-PDF)
- Report year: 2025 · Verified: 2026-11-11
- Web page: https://www.fieldstonewater.com/water/north-valley-stream
- JSON: https://www.fieldstonewater.com/api/v1/towns/north-valley-stream

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. The report carries 1 notice: No violation notice printed. Report states the treated water system had no violations and did not violate any MCL or other water quality standard in 2025; Statistics At-a-Glance prints Violations of Standards: None. 100% of North Valley Stream's land lies inside a public water service area (Water Authority of Western Nassau), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

## Summary

Reported above a limit: Iron, Acetaldehyde, Formaldehyde.
Detected: Alkalinity, Ammonia (as N), Barium, Calcium, Chloride, Free Chlorine, Hexavalent Chromium, Copper, Corrosivity (LSI), Total Dissolved Solids, Hardness (total), Lead, Magnesium, Manganese, Nickel, Nitrate, Odor, Perchlorate, Phosphorus, pH, Selenium, Sodium, Sulfate, Zinc, Chlorodifluoromethane, Chloromethane, Combined Radium 226/228, Gross alpha, Gross beta, Uranium, 1,4-Dioxane, Chlordane, Dieldrin, Heptachlor epoxide, PFOS, PFOA, Chlorate, Glyoxal, Methyl glyoxal, Total Trihalomethanes, PFBA, PFNA, PFPeA, PFBS, PFHxS, PFHpA, PFHxA, PFOS, PFOS, PFOS, PFOA, PFOA, PFBA, PFPeA, PFPeA, PFBS, PFHxS, PFHxS, PFHpA, PFHpA, PFHxA, PFHxA.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Alkalinity | 288 | 2.8 to 288 | mg/L | — | No regulatory limit | detected | no | — |
| Ammonia (as N) | 2.8 | ND to 2.8 | mg/L | — | No regulatory limit | detected | no | — |
| Barium | 0.04 | ND to 0.04 | mg/L | 2 | EPA MCL | detected | no | — |
| Calcium | 24.5 | 1.5 to 24.5 | mg/L | — | No regulatory limit | detected | no | — |
| Chloride | 95.7 | 4.1 to 95.7 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Free Chlorine | 1.3 | 0.53 to 1.3 | mg/L | 4 | EPA MRDL | detected | no | — |
| Hexavalent Chromium | 0.31 | ND to 0.31 | µg/L | — | No regulatory limit | detected | no | — |
| Copper | 0.14 | 0.0063 to 0.53 | mg/L | 1.3 | EPA action level | detected | no | — |
| Corrosivity (LSI) | -5.4 | -0.71 to -5.4 | SI | — | No regulatory limit | detected | no | — |
| Total Dissolved Solids | 251 | 59 to 251 | mg/L | — | No regulatory limit | detected | no | — |
| Hardness (total) | 109 | 8.3 to 109 | mg/L | — | No regulatory limit | detected | no | — |
| Iron | 340 | ND to 340 | µg/L | 300 | NYS secondary standard | exceeds | yes | — |
| Lead | 1.4 | ND to 5.6 | µg/L | 15 | EPA action level | detected | no | — |
| Magnesium | 12.3 | 0.95 to 12.3 | mg/L | — | No regulatory limit | detected | no | — |
| Manganese | 41 | ND to 41 | µg/L | 300 | NYS secondary standard | detected | no | — |
| Nickel | 8.4 | ND to 8.4 | µg/L | — | No regulatory limit | detected | no | — |
| Nitrate | 6.5 | ND to 6.5 | mg/L | 10 | EPA MCL | detected | no | — |
| Odor | 1 | ND to 1 | Units | 3 | NYS secondary standard | detected | no | — |
| Perchlorate | 2.4 | ND to 2.4 | µg/L | 18 | NYS MCL | detected | no | — |
| Phosphorus | 0.44 | ND to 0.44 | mg/L | — | No regulatory limit | detected | no | — |
| pH | 8.5 | 7.4 to 8.5 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Selenium | 0.0032 | ND to 0.0032 | mg/L | 0.05 | EPA MCL | detected | no | — |
| Sodium | 59 | 3.2 to 59 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Sulfate | 46.8 | 7.1 to 46.8 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Zinc | 0.77 | ND to 0.77 | mg/L | 5 | NYS secondary standard | detected | no | — |
| Chlorodifluoromethane | 0.57 | ND to 0.57 | µg/L | 5 | EPA MCL | detected | no | — |
| Chloromethane | 0.74 | ND to 0.74 | µg/L | 5 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 4.422 | 0.491 to 4.422 | pCi/L | 5 | EPA MCL | detected | no | — |
| Gross alpha | 4.560 | -1.340 to 4.560 | pCi/L | 15 | EPA MCL | detected | no | — |
| Gross beta | 5.2 | 0.138 to 5.2 | pCi/L | 50 | EPA MCL | detected | no | — |
| Uranium | 0.485 | -0.024 to 0.485 | µg/L | 30 | EPA MCL | detected | no | — |
| 1,4-Dioxane | 0.84 | ND to 0.84 | µg/L | 1 | NYS MCL | detected | no | — |
| Chlordane | 0.60 | ND to 0.60 | µg/L | 2 | EPA MCL | detected | no | — |
| Dieldrin | 0.11 | ND to 0.11 | µg/L | 5 | EPA MCL | detected | no | — |
| Heptachlor epoxide | 0.048 | ND to 0.048 | µg/L | 0.2 | EPA MCL | detected | no | — |
| PFOS | 2.41 | ND to 2.41 | ng/L | 10 | NYS MCL | detected | no | — |
| PFOA | 6.22 | ND to 6.22 | ng/L | 10 | NYS MCL | detected | no | — |
| Acetaldehyde | 369 | ND to 369 | µg/L | 50 | EPA MCL | exceeds | yes | — |
| Chlorate | 297 | ND to 297 | µg/L | — | No regulatory limit | detected | no | — |
| Formaldehyde | 360 | ND to 360 | µg/L | 50 | EPA MCL | exceeds | yes | — |
| Glyoxal | 29.4 | ND to 29.4 | µg/L | 50 | EPA MCL | detected | no | — |
| Methyl glyoxal | 6 | ND to 6 | µg/L | 50 | EPA MCL | detected | no | — |
| Total Trihalomethanes | 3.60 | ND to 10.30 | µg/L | 80 | EPA MCL | detected | no | — |
| PFBA | 8.92 | ND to 8.92 | ng/L | — | No regulatory limit | detected | no | — |
| PFNA | 1.93 | ND to 1.93 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 13.0 | ND to 13.0 | ng/L | — | No regulatory limit | detected | no | — |
| PFBS | 3.46 | ND to 3.46 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxS | 3.44 | ND to 3.44 | ng/L | — | No regulatory limit | detected | no | — |
| PFHpA | 2.85 | ND to 2.85 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxA | 9.30 | ND to 9.30 | ng/L | — | No regulatory limit | detected | no | — |
| PFOS | 2.61 | ND to 2.61 | ng/L | — | No regulatory limit | detected | no | — |
| PFOS | 5.8 | ND to 5.8 | ng/L | 10 | NYS MCL | detected | no | — |
| PFOS | 6.1 | 6.1 to 6.1 | ng/L | 10 | NYS MCL | detected | no | — |
| PFOA | 10.0 | ND to 10.0 | ng/L | 10 | NYS MCL | detected | no | — |
| PFOA | 10.0 | 10.0 to 10.0 | ng/L | 10 | NYS MCL | detected | no | — |
| PFBA | 7.1 | ND to 7.1 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 9.5 | ND to 9.5 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 4.2 | 4.2 to 4.2 | ng/L | — | No regulatory limit | detected | no | — |
| PFBS | 3.6 | ND to 3.6 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxS | 4.5 | ND to 4.5 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxS | 4.1 | 4.1 to 4.1 | ng/L | — | No regulatory limit | detected | no | — |
| PFHpA | 3.4 | ND to 3.4 | ng/L | — | No regulatory limit | detected | no | — |
| PFHpA | 3.1 | 3.1 to 3.1 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxA | 7.4 | ND to 7.4 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxA | 4.0 | 4.0 to 4.0 | ng/L | — | No regulatory limit | detected | no | — |
| HFPO-DA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 26 |

## Sources

- Water Authority of Western Nassau County 2025 Annual Water Quality Report: https://www.gardencityny.net/DocumentCenter/View/4147/2026-Water-Authority-of-Western-Nassau-County-Water-Quality-Report-PDF
- EPA UCMR 5 PFAS results, 2023–2025 (entry-point samples): https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Liberty Utilities New York - Lynbrook | NY2902835 | 30 | 5 | 30 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902835 |
| Water Authority of Western Nassau | NY2902830 | 0 | 0 | 1 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902830 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For North Valley Stream, the numbers point first to under-sink reverse osmosis, whole-house carbon filtration, and private well treatment: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 6.5 mg/L with samples up to 6.5 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. PFOA/PFOS reached 6.22 ng/L (ppt) in at least one sample — under New York's 10 ppt limit but at or above the 4.0 ppt federal MCL, with federal compliance due April 26, 2029. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 59 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 2.4 µg/L (limit 18). The supplier's 90th-percentile lead result was 0.0014 mg/L (1 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.
- **Whole-House Carbon Filtration** (recommended): Chlorine residual 1.3 mg/L. Free chlorine averaged 1.3 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair.
- **Private Well Treatment** (recommended): Iron up to 340 µg/L in some wells. Iron peaked at 340 µg/L (average 340) against the 300 µg/L standard: orange staining on fixtures and laundry in the homes that get it. On a public supply this calls for an iron filter, the same oxidizing equipment used in a well package, only if you see the staining.
- **Whole-House + Softener Combo** (worth considering): Hardness 109 mg/L, about 6.4 grains per gallon. At 109 mg/L (6.4 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/north-valley-stream, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license