# Water quality in Plandome Manor, NY (Nassau County)

- Water source: Public water, some private wells
- Supplier / district: Port Washington Water District
- Supplier contact: Port Washington Water District (https://pwwd.org/wordpress/wp-content/uploads/2026/05/PWWD-2025-ADWQR.pdf)
- Report year: 2025 · Verified: 2026-11-11
- Web page: https://www.fieldstonewater.com/water/plandome-manor
- JSON: https://www.fieldstonewater.com/api/v1/towns/plandome-manor

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. About 35% of Plandome Manor's land lies inside a public water service area (Port Washington Water District), per the NYS Department of Health boundaries EPA publishes; the rest is on private wells. These results apply only to public water.

## Summary

No contaminant averaged above its limit in the reported year.
Individual samples above the limit: Lead (high 17.6 vs limit 15 µg/L).
Detected: Barium, Bromide, Calcium, Chlorate, Chloride, Copper, Magnesium, Nickel, Selenium, Sodium, Sulfate, Zinc, Nitrate, Nitrate-Nitrite (as N), Calcium hardness, Corrosivity (LSI), pH, Alkalinity, Total Dissolved Solids, Hardness (total), Free Chlorine, 1,1-Dichloroethane, Gross alpha, Gross beta, Combined Radium 226/228, Uranium, 1,4-Dioxane, Perchlorate, PFOA, PFOS, Copper, Lead, Bromoform, Chloroform, Dibromochloromethane, Formaldehyde, Glyoxal, Propanal, Total Trihalomethanes, PFBA, PFHpA, PFHxS, PFHxA, PFPeA, PFNA.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Barium | 0.037 | 0.011 to 0.037 | mg/L | 2 | EPA MCL | detected | no | — |
| Bromide | 0.053 | 0.053 to 0.053 | mg/L | — | No regulatory limit | detected | no | — |
| Calcium | 39.3 | 21.1 to 39.3 | mg/L | — | No regulatory limit | detected | no | — |
| Chlorate | 145 | 23.1 to 145 | mg/L | 250 | EPA MCL | detected | no | — |
| Chloride | 106 | 71.5 to 106 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Copper | 0.02 | ND to 0.02 | mg/L | 1.3 | EPA action level | detected | no | — |
| Magnesium | 18.2 | 11.3 to 18.2 | mg/L | — | No regulatory limit | detected | no | — |
| Nickel | 0.0012 | 0.00091 to 0.0012 | mg/L | — | No regulatory limit | detected | no | — |
| Selenium | 2.9 | ND to 2.9 | µg/L | 50 | EPA MCL | detected | no | — |
| Sodium | 39 | 22 to 39 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Sulfate | 84.9 | 10.9 to 84.9 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Zinc | 0.026 | ND to 0.026 | mg/L | 5 | NYS secondary standard | detected | no | — |
| Nitrate | 5.8 | 3.4 to 5.8 | mg/L | 10 | EPA MCL | detected | no | — |
| Nitrate-Nitrite (as N) | 5.8 | 3.4 to 5.8 | mg/L | 10 | EPA MCL | detected | no | — |
| Calcium hardness | 98.1 | 17.7 to 98.1 | mg/L | — | No regulatory limit | detected | no | — |
| Corrosivity (LSI) | -0.65 | -3.71 to -0.65 | — | — | No regulatory limit | detected | no | — |
| pH | 7.6 | 6.1 to 7.6 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Alkalinity | 84.0 | 31.2 to 84.0 | mg/L | — | No regulatory limit | detected | no | — |
| Total Dissolved Solids | 297 | 58 to 297 | mg/L | — | No regulatory limit | detected | no | — |
| Hardness (total) | 173 | 35.2 to 173 | mg/L | — | No regulatory limit | detected | no | — |
| Free Chlorine | 0.86 | 0.23 to 1.3 | mg/L | 4 | EPA MRDL | detected | no | — |
| 1,1-Dichloroethane | 0.96 | ND to 0.96 | µg/L | 5 | EPA MCL | detected | no | — |
| Gross alpha | 4.21 | 0 to 4.21 | pCi/L | 15 | EPA MCL | detected | no | — |
| Gross beta | 4.62 | 0 to 4.62 | pCi/L | 50 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 2.33 | 0 to 2.33 | pCi/L | 5 | EPA MCL | detected | no | — |
| Uranium | 2.105 | 0 to 2.105 | µg/L | 30 | EPA MCL | detected | no | — |
| 1,4-Dioxane | 0.35 | ND to 0.35 | µg/L | 1 | NYS MCL | detected | no | — |
| Perchlorate | 1.1 | ND to 1.1 | µg/L | 18 | NYS MCL | detected | no | — |
| PFOA | 8.03 | ND to 8.03 | ng/L | 10 | NYS MCL | detected | no | — |
| PFOS | 2.7 | ND to 2.7 | ng/L | 10 | NYS MCL | detected | no | — |
| Copper | 0.15 | 0.013 to 0.33 | mg/L | 1.3 | EPA action level | detected | no | — |
| Lead | 3.6 | ND to 17.6 | µg/L | 15 | EPA action level | detected | yes | — |
| Bromoform | 1.2 | ND to 1.2 | µg/L | 80 | EPA MCL | detected | no | — |
| Chloroform | 1.5 | ND to 1.5 | µg/L | 80 | EPA MCL | detected | no | — |
| Dibromochloromethane | 1.2 | ND to 1.2 | µg/L | 80 | EPA MCL | detected | no | — |
| Formaldehyde | 34.6 | ND to 34.6 | µg/L | 80 | EPA MCL | detected | no | — |
| Glyoxal | 14.3 | ND to 14.3 | µg/L | 80 | EPA MCL | detected | no | — |
| Propanal | 9.3 | ND to 9.3 | µg/L | 80 | EPA MCL | detected | no | — |
| Total Trihalomethanes | 3.8 | ND to 3.8 | µg/L | 80 | EPA MCL | detected | no | — |
| PFBA | 5.01 | ND to 5.01 | ng/L | — | No regulatory limit | detected | no | — |
| PFHpA | 2.0 | ND to 2.0 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxS | 2.68 | ND to 2.68 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxA | 3.44 | ND to 3.44 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 5.96 | ND to 5.96 | ng/L | — | No regulatory limit | detected | no | — |
| PFNA | — | ND to 0.0042 | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | detected | no | 18 |
| PFBS | — | ND to ND | µg/L | — | No regulatory limit | not-detected | no | 18 |
| HFPO-DA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 18 |

## Sources

- Port Washington Water District 2025 Annual Water Quality Report: https://pwwd.org/wordpress/wp-content/uploads/2026/05/PWWD-2025-ADWQR.pdf
- EPA UCMR 5 PFAS results, 2023–2025 (entry-point samples): https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Manhasset Lakeville Water District | NY2902836 | 0 | 0 | 0 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902836 |
| Port Washington Water District | NY2912267 | 1 | 1 | 1 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2912267 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For Plandome Manor, the numbers point first to under-sink reverse osmosis, whole-house carbon filtration, and whole-house + softener combo: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 5.8 mg/L with samples up to 5.8 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. PFOA/PFOS reached 8.03 ng/L (ppt) in at least one sample — under New York's 10 ppt limit but at or above the 4.0 ppt federal MCL, with federal compliance due April 26, 2029. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 39 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 1.1 µg/L (limit 18). The supplier's 90th-percentile lead result was 0.0036 mg/L (4 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.
- **Whole-House Carbon Filtration** (recommended): Chlorine residual 0.86 mg/L. Free chlorine averaged 0.86 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 1.5 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk.
- **Whole-House + Softener Combo** (recommended): Hardness 173 mg/L, about 10.1 grains per gallon. At 173 mg/L (10.1 gpg) this is hard water: it scales water heaters, spots glassware and leaves film on skin. A softener paired with carbon is the standard fix above 7 grains.
- **Private Well Treatment** (worth considering): Private wells in part of the community. Part of Plandome Manor is on private wells that none of these figures cover; a well needs its own test, and a well package is sized to what it finds.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/plandome-manor, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license