# Water quality in Searingtown, NY (Nassau County)

- Water source: Public water
- Supplier / district: Albertson Water District
- Supplier contact: Albertson Water District (https://albertsonwater.org/wordpress/wp-content/uploads/2026/05/AWD-2025-Water-Report.pdf) — Serves this community per the NYS DOH service-area boundary EPA publishes.
- Supplier contact: Garden City Park Water District (https://www.gcpwater.org/wp-content/uploads/2026/05/26.04.28-2025-GCPK-Drinking-Water-Quality-Report-FINAL1.pdf) — Also serves about 33% of this community per the NYS DOH service-area boundary.
- Report year: 2025 · Verified: 2026-11-11
- Web page: https://www.fieldstonewater.com/water/searingtown
- JSON: https://www.fieldstonewater.com/api/v1/towns/searingtown

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. Albertson Water District's report does not name Searingtown in its service area. The service-area boundary the NYS Department of Health supplies to EPA places most of Searingtown inside the district (https://www.epa.gov/ground-water-and-drinking-water/community-water-system-service-area-boundaries). That mapping is not in the report. The report carries 2 notices: MONITORING VIOLATION NOTICE - 'Monitoring Requirements Not Met for the Albertson Water District'. During the 2nd, 3rd & 4th quarters in 2024 and the 1st quarter of 2025, the District did not monitor or test for dieldrin (EPA Analytical Method 505) at Well 1 and Well 5 (required 1 sample quarterly; 0 samples taken for the 1st quarter of 2025; samples taken 4/17/2025). 'Even though this was not an emergency ... There is nothing you need to do at this time.' Dieldrin samples were obtained and tested during the 2nd, 3rd, and 4th quarters of 2025, yielding results below the MCL; a system of checks and balances has been instituted. Notice date distributed: April 2025. Page 1 also states: 'We failed to adequately sample our wells for dieldrin in the first quarter of 2025 and we were issued a drinking water violation.' Total coliform: In July 2025, total coliforms were detected in 2 of 471 routine compliance samples (0.42% samples positive); repeat samples were negative; <5% so no Level 1 assessment triggered; E. coli not detected. Not a violation (Violation column 'No'). 100% of Searingtown's land lies inside a public water service area (Albertson Water District and others), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

## Summary

No contaminant averaged above its limit in the reported year.
Detected: Total Coliform, Barium, Calcium, Chloride, Magnesium, Nickel, Perchlorate, Sodium, Sulfate, Nitrate, Nitrate-Nitrite (as N), Nitrite, Calcium hardness, Corrosivity (LSI), Odor, pH, Alkalinity, Total Dissolved Solids, Hardness (total), Free Chlorine, 1,4-Dioxane, Benzo(a)pyrene, DEHP, Dieldrin, PFOA, PFOS, Total Trihalomethanes, Bromoform, Dibromochloromethane, Tetrachloroethene (PCE), Gross alpha, Gross beta, Combined Radium 226/228, Uranium, Copper, PFBA, PFHpA, PFHxS, PFHxA, PFNA, PFPeA, PFOS.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Total Coliform | 0.42% samples positive | — | n/a | 5 | EPA MCL | detected | no | — |
| Barium | 0.019 | 0.0029 to 0.019 | mg/L | 2 | EPA MCL | detected | no | — |
| Calcium | 16.8 | 8.2 to 16.8 | mg/L | — | No regulatory limit | detected | no | — |
| Chloride | 77.5 | 20.8 to 77.5 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Magnesium | 7.9 | 4.1 to 7.9 | mg/L | — | No regulatory limit | detected | no | — |
| Nickel | 0.00079 | ND to 0.00079 | mg/L | — | No regulatory limit | detected | no | — |
| Perchlorate | 1.2 | ND to 1.2 | µg/L | 18 | NYS MCL | detected | no | — |
| Sodium | 35.5 | 10.5 to 35.5 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Sulfate | 23.6 | 10.6 to 23.6 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Nitrate | 3 | 2.5 to 3 | mg/L | 10 | EPA MCL | detected | no | — |
| Nitrate-Nitrite (as N) | 3 | 2.5 to 3 | mg/L | 10 | EPA MCL | detected | no | — |
| Nitrite | 0.077 | ND to 0.077 | mg/L | 1 | EPA MCL | detected | no | — |
| Calcium hardness | 41.9 | 20.4 to 41.9 | mg/L | — | No regulatory limit | detected | no | — |
| Corrosivity (LSI) | -1.14 | -2.33 to -1.14 | — | — | No regulatory limit | detected | no | — |
| Odor | 1 | ND to 1 | Units | — | No regulatory limit | detected | no | — |
| pH | 7.6 | 6.8 to 7.6 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Alkalinity | 24.7 | 12.6 to 24.7 | mg/L | — | No regulatory limit | detected | no | — |
| Total Dissolved Solids | 185 | 80 to 185 | mg/L | — | No regulatory limit | detected | no | — |
| Hardness (total) | 74.4 | 37.1 to 74.4 | mg/L | — | No regulatory limit | detected | no | — |
| Free Chlorine | 0.872 | 0.5 to 1.4 | mg/L | 4 | EPA MRDL | detected | no | — |
| 1,4-Dioxane | 0.25 | 0.05 to 0.25 | µg/L | 1 | NYS MCL | detected | no | — |
| Benzo(a)pyrene | 0.027 | ND to 0.027 | ng/L | 200 | EPA MCL | detected | no | — |
| DEHP | 2.3 | ND to 2.3 | µg/L | 6 | EPA MCL | detected | no | — |
| Dieldrin | 0.071 | 0.051 to 0.071 | µg/L | 5 | EPA MCL | detected | no | — |
| PFOA | 8.01 | ND to 8.01 | ng/L | 10 | NYS MCL | detected | no | — |
| PFOS | 1.94 | ND to 1.94 | ng/L | 10 | NYS MCL | detected | no | — |
| Total Trihalomethanes | 1.3 | ND to 1.3 | µg/L | 80 | EPA MCL | detected | no | — |
| Bromoform | 0.58 | ND to 0.58 | µg/L | 80 | EPA MCL | detected | no | — |
| Dibromochloromethane | 0.68 | ND to 0.68 | µg/L | 80 | EPA MCL | detected | no | — |
| Tetrachloroethene (PCE) | 3.2 | ND to 3.2 | µg/L | 5 | EPA MCL | detected | no | — |
| Gross alpha | 1.32 | -0.479 to 1.32 | pCi/L | 15 | EPA MCL | detected | no | — |
| Gross beta | 3.5 | 2.12 to 3.5 | pCi/L | 50 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 1.13 | 1.11 to 1.13 | pCi/L | 5 | EPA MCL | detected | no | — |
| Uranium | 0.048 | 0.033 to 0.048 | µg/L | 30 | EPA MCL | detected | no | — |
| Copper | 0.035 | 0.032 to 0.052 | mg/L | 1.3 | EPA action level | detected | no | — |
| Lead | ND | ND to 1.2 | µg/L | 15 | EPA action level | not-detected | no | — |
| PFBA | 7.03 | ND to 7.03 | ng/L | — | No regulatory limit | detected | no | — |
| PFHpA | 2.59 | ND to 2.59 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxS | 4.65 | ND to 4.65 | ng/L | — | No regulatory limit | detected | no | — |
| PFHxA | 3.27 | ND to 3.27 | ng/L | — | No regulatory limit | detected | no | — |
| PFNA | 7.62 | ND to 7.62 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 8.79 | ND to 8.79 | ng/L | — | No regulatory limit | detected | no | — |
| PFOS | 3.45 | ND to 3.45 | ng/L | — | No regulatory limit | detected | no | — |
| HFPO-DA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 8 |
| PFBS | — | ND to ND | µg/L | — | No regulatory limit | not-detected | no | 8 |

## Sources

- Albertson Water District 2025 Annual Water Quality Report: https://albertsonwater.org/wordpress/wp-content/uploads/2026/05/AWD-2025-Water-Report.pdf
- EPA UCMR 5 PFAS results, 2023–2025 (entry-point samples): https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Garden City Park Water District | NY2902825 | 0 | 0 | 0 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902825 |
| Albertson Water District | NY2902815 | 304 | 0 | 344 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902815 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For Searingtown, the numbers point first to under-sink reverse osmosis and whole-house carbon filtration: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 3 mg/L (limit 10), moderate but present; reverse osmosis reduces it at the tap. PFOA/PFOS reached 8.01 ng/L (ppt) in at least one sample — under New York's 10 ppt limit but at or above the 4.0 ppt federal MCL, with federal compliance due April 26, 2029. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 35.5 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 1.2 µg/L (limit 18).
- **Whole-House Carbon Filtration** (recommended): Solvent traces and chlorine in the supply. Free chlorine averaged 0.872 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Solvent traces were detected: Tetrachloroethene (PCE) up to 3.2 µg/L (limit 5 each). Whether a whole-house carbon model reduces those solvents is on that model's data sheet.
- **Whole-House + Softener Combo** (worth considering): Hardness 74.4 mg/L, about 4.4 grains per gallon. At 74.4 mg/L (4.4 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/searingtown, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license