# Water quality in St. James, NY (Suffolk County)

- Water source: Public water
- Supplier / district: St. James Water District (SCWA-supplied)
- Supplier contact: St. James Water District (https://www.smithtownny.gov/504/Annual-Water-Quality-Reports) — Roughly the St. James Fire District boundaries; about 11,756 people through 3,355 connections.
- Supplier contact: Suffolk County Water Authority (https://www.scwa.com, (631) 698-9500) — Source supplier: the district buys all of its water from SCWA through 11 interconnections and owns no wells.
- Report year: 2025 · Verified: 2026-09-14
- Web page: https://www.fieldstonewater.com/water/st-james
- JSON: https://www.fieldstonewater.com/api/v1/towns/st-james

From the district's report: it publishes ranges only, sampled in the distribution system; PFAS, 1,4-dioxane and VOC testing is done by SCWA at the source wells and is not in this report. The report notes nitrate above 5 mg/L but below the 10 mg/L limit and includes the infant advisory. 100% of St. James's land lies inside a public water service area (St. James Water District and others), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

## Summary

No contaminant averaged above its limit in the reported year.
Detected: Lead, Copper, Nitrate, Barium, Odor, Chloride, Manganese, Cyanide, Chloroform, Bromodichloromethane, Dibromochloromethane, Total Trihalomethanes, Chlorate, Free Chlorine, Hardness (total), Calcium Hardness, Specific Conductance, Sodium, pH.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Lead | ND | ND to 1.4 | ug/L | 15 | EPA action level | detected | no | 33 |
| Copper | 0.33 | 0.042 to 0.41 | mg/L | 1.3 | EPA action level | detected | no | 33 |
| Nitrate | — | 0.3 to 5.5 | mg/L | 10 | EPA MCL | detected | no | — |
| Barium | — | 0.002 to 0.021 | mg/L | 2 | EPA MCL | detected | no | — |
| Odor | — | 1.0 to 1.0 | — | 3 | NYS MCL | detected | no | — |
| Chloride | — | 8.7 to 51.4 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Manganese | — | ND to 0.055 | ug/L | 300 | NYS secondary standard | detected | no | — |
| Cyanide | — | ND to 16.4 | ug/L | 200 | EPA MCL | detected | no | — |
| Chloroform | — | 0.56 to 1.3 | ug/L | 80 (TTHM sum) | EPA MCL | detected | no | — |
| Bromodichloromethane | — | ND to 1.3 | ug/L | 80 (TTHM sum) | EPA MCL | detected | no | — |
| Dibromochloromethane | — | ND to 0.69 | ug/L | 80 (TTHM sum) | EPA MCL | detected | no | — |
| Total Trihalomethanes | — | 0.56 to 3.2 | ug/L | 80 | EPA MCL | detected | no | — |
| Chlorate | — | 85.7 to 90.7 | ug/L | — | No regulatory limit | detected | no | — |
| Free Chlorine | — | 0.43 to 1.48 | mg/L | 4 | EPA MRDL | detected | no | — |
| Hardness (total) | — | 68.4 to 120.0 | mg/L | — | No regulatory limit | detected | no | — |
| Calcium Hardness | — | 46.4 to 72.7 | mg/L | — | No regulatory limit | detected | no | — |
| Specific Conductance | — | 181 to 419 | umhos/cm | — | No regulatory limit | detected | no | — |
| Sodium | — | 9.4 to 32.3 | mg/L | — | No regulatory limit | detected | no | — |
| pH | — | 6.94 to 7.52 | Units | — | No regulatory limit | detected | no | — |

## Sources

- St. James Water District 2025 Drinking Water Quality Report: https://www.smithtownny.gov/DocumentCenter/View/9321/260319---2025-SJWD-Drinking-Water-Quality-Report---FINAL1PDF

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Suffolk County Water Authority | NY5110526 | 3 | 0 | 7 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY5110526 |
| St. James Water District | NY5103266 | 0 | 0 | 0 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY5103266 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For St. James, the numbers point first to under-sink reverse osmosis, whole-house carbon filtration, and whole-house + softener combo: dissolved contaminants close to their limits.

- **Under-Sink Reverse Osmosis** (recommended): Dissolved contaminants close to their limits. Nitrate averaged 5.5 mg/L with samples up to 5.5 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. Sodium averaged 32.3 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets.
- **Whole-House Carbon Filtration** (recommended): Chlorine residual 1.48 mg/L. Free chlorine averaged 1.48 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 1.3 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk.
- **Whole-House + Softener Combo** (recommended): Hardness 120 mg/L, about 7.0 grains per gallon. At 120 mg/L (7.0 gpg) this is hard water: it scales water heaters, spots glassware and leaves film on skin. A softener paired with carbon is the standard fix above 7 grains.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/st-james, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license