# Water quality in West Hempstead, NY (Nassau County)

- Water source: Public water, some private wells
- Supplier / district: West Hempstead Water District
- Supplier contact: West Hempstead Water District (https://westhempsteadwater.org/wp-content/uploads/2026/05/2025-WHWD-Drinking-Water-Quality-Report.pdf)
- Supplier contact: Liberty New York Water - Lynbrook Operations District (https://new-york-water.libertyutilities.com/uploads/Lynbrook_CCR.pdf) — Also serves part of this community.
- Report year: 2025 · Verified: 2026-11-11
- Web page: https://www.fieldstonewater.com/water/west-hempstead
- JSON: https://www.fieldstonewater.com/api/v1/towns/west-hempstead

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. The report carries 1 notice: NOTICE OF VIOLATION (monitoring): 'Our water system violated drinking water requirements over the past year... During the January 2025 - December 2025 period. We did not complete monitoring for Nitrate and Nitrite from Wells 6, 10, & 11, and therefore cannot be sure of the quality of your drinking water during that time.' Table: Contaminant Nitrate & Nitrite; Required Sampling Frequency 1 sample every year; Number of Samples Taken 0; When Samples Should Have Been Taken 2025; When Samples Were Taken March 2026. 'Nitrate and nitrite samples were taken in March 2026 for Well Nos. 10, and 11. Well Nos. 10 and 11 are both non-detect for nitrate and nitrite. Well No. 6 is currently out of service for well rehabilitation and samples cannot be taken at this time.' Notice sent by West Hempstead Water District, State Water System ID#:2902857. About 79% of West Hempstead's land lies inside a public water service area (West Hempstead Water District and others), per the NYS Department of Health boundaries EPA publishes; the rest is on private wells. These results apply only to public water.

## Summary

No contaminant averaged above its limit in the reported year.
Individual samples above the limit: Lead (high 103.0 vs limit 15 µg/L).
Detected: Copper, Lead, Barium, Calcium, Chloride, Iron, Magnesium, Nickel, Sodium, Sulfate, Zinc, Arsenic, Copper, Nitrate, Nitrate-Nitrite (as N), Bromodichloromethane, Bromoform, Dibromochloromethane, Total Trihalomethanes, Gross alpha, Gross beta, Combined Radium 226/228, Uranium, Dichlorodifluoromethane, Free Chlorine, pH, Hardness (total), Calcium hardness, Alkalinity, Total Dissolved Solids, Turbidity, Odor, Color, 1,4-Dioxane, PFOA, Bromide, PFHxA, PFPeA.

## Contaminants

| Contaminant | Average | Range | Unit | Limit | Limit source | Status | Peak above limit | Samples |
|---|---|---|---|---|---|---|---|---|
| Copper | 0.24 | 0.0038 to 0.28 | mg/L | 1.3 | EPA action level | detected | no | — |
| Lead | 1.1 | ND to 103.0 | µg/L | 15 | EPA action level | detected | yes | — |
| Barium | 0.0024 | ND to 0.0024 | mg/L | 2.0 | EPA MCL | detected | no | — |
| Calcium | 8.1 | 3.0 to 8.1 | mg/L | — | No regulatory limit | detected | no | — |
| Chloride | 19.4 | 13.8 to 19.4 | mg/L | 250.0 | NYS secondary standard | detected | no | — |
| Iron | 90.0 | ND to 90.0 | µg/L | 300 | NYS secondary standard | detected | no | — |
| Magnesium | 4.5 | 1.8 to 4.5 | mg/L | — | No regulatory limit | detected | no | — |
| Nickel | 0.003 | 0.00062 to 0.003 | mg/L | — | No regulatory limit | detected | no | — |
| Sodium | 27.3 | 6.2 to 27.3 | mg/L | — | NYS guidance (20 mg/L for sodium-restricted diets) | detected | no | — |
| Sulfate | 18.8 | 13.3 to 18.8 | mg/L | 250 | NYS secondary standard | detected | no | — |
| Zinc | 0.03 | ND to 0.03 | mg/L | 5.0 | NYS secondary standard | detected | no | — |
| Arsenic | 1.2 | ND to 1.2 | µg/L | 10 | EPA MCL | detected | no | — |
| Copper | 0.012 | ND to 0.012 | mg/L | 1.3 | EPA action level | detected | no | — |
| Nitrate | 1.3 | ND to 1.3 | mg/L | 10 | EPA MCL | detected | no | — |
| Nitrate-Nitrite (as N) | 1.3 | ND to 1.3 | mg/L | 10 | EPA MCL | detected | no | — |
| Bromodichloromethane | 0.75 | ND to 0.75 | µg/L | 50 | EPA MCL | detected | no | — |
| Bromoform | 0.7 | ND to 0.7 | µg/L | 50 | EPA MCL | detected | no | — |
| Dibromochloromethane | 1.2 | ND to 1.2 | µg/L | 50 | EPA MCL | detected | no | — |
| Total Trihalomethanes | 2.6 | ND to 2.6 | µg/L | 80 | EPA MCL | detected | no | — |
| Gross alpha | 1.4 | -1.06 to 1.4 | pCi/L | 15 | EPA MCL | detected | no | — |
| Gross beta | 1.71 | 0.32 to 1.71 | pCi/L | 50 | EPA MCL | detected | no | — |
| Combined Radium 226/228 | 0.924 | 0.0537 to 0.924 | pCi/L | 5 | EPA MCL | detected | no | — |
| Uranium | 0.70 | ND to 0.70 | µg/L | 30 | EPA MCL | detected | no | — |
| Dichlorodifluoromethane | 2.4 | ND to 2.4 | µg/L | 5 | EPA MCL | detected | no | — |
| Free Chlorine | 1.65 | 0.32 to 1.65 | mg/L | 4.0 | EPA MRDL | detected | no | — |
| pH | 8.62 | 7.3 to 8.62 | Units | — | NYS guidance range 7.5–8.5 | detected | no | — |
| Hardness (total) | 39.0 | 15.0 to 39.0 | mg/L | — | No regulatory limit | detected | no | — |
| Calcium hardness | 20.3 | 7.6 to 20.3 | mg/L | — | No regulatory limit | detected | no | — |
| Alkalinity | 42.1 | 1.2 to 42.1 | mg/L | — | No regulatory limit | detected | no | — |
| Total Dissolved Solids | 93.0 | ND to 93.0 | mg/L | — | No regulatory limit | detected | no | — |
| Turbidity | 3.8 | ND to 3.8 | NTU | 5 | EPA MCL | detected | no | — |
| Odor | 1.0 | ND to 1.0 | Units | 3 | NYS secondary standard | detected | no | — |
| Color | 9.0 | ND to 9.0 | Units | 15 | NYS secondary standard | detected | no | — |
| 1,4-Dioxane | 0.056 | ND to 0.056 | µg/L | 1.0 | NYS MCL | detected | no | — |
| PFOA | 3.19 | ND to 3.19 | ng/L | 10 | NYS MCL | detected | no | — |
| PFOS | ND | ND to ND | ng/L | 10 | NYS MCL | not-detected | no | — |
| Bromide | 0.095 | 0.079 to 0.095 | mg/L | — | No regulatory limit | detected | no | — |
| PFHxA | 2.28 | ND to 2.28 | ng/L | — | No regulatory limit | detected | no | — |
| PFPeA | 2.74 | ND to 2.74 | ng/L | — | No regulatory limit | detected | no | — |
| HFPO-DA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 4 |
| PFNA | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 4 |
| PFHxS | — | ND to ND | µg/L | — | EPA MCL of 0.010 µg/L takes effect 2029; no limit in force | not-detected | no | 4 |
| PFBS | — | ND to ND | µg/L | — | No regulatory limit | not-detected | no | 4 |

## Sources

- West Hempstead Water District 2025 Annual Water Quality Report: https://westhempsteadwater.org/wp-content/uploads/2026/05/2025-WHWD-Drinking-Water-Quality-Report.pdf
- EPA UCMR 5 PFAS results, 2023–2025 (entry-point samples): https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule

## EPA compliance record (suppliers serving this community's ZIP codes)

| System | EPA ID | Violations | Health-based | All time | Window | EPA report |
|---|---|---|---|---|---|---|
| Liberty Utilities New York - Lynbrook | NY2902835 | 30 | 5 | 30 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902835 |
| Hempstead (Village) | NY2902827 | 1 | 0 | 4 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902827 |
| West Hempstead Water District | NY2902857 | 1 | 0 | 1 | 2022–2026 | https://echo.epa.gov/detailed-facility-report?fid=NY2902857 |

## Notes on this data

- Public-water figures are annual results published by the water supplier in its Annual Drinking Water Quality Report (CCR), reported across all wells feeding a distribution area. They describe water leaving the supplier, not the tap in a specific home.
- Private wells are not covered by any public report. Well owners need their own test.
- Status compares the reported average (or the range high where no average is published) to the regulatory limit. 'exceeds' is a numeric comparison, not a regulatory violation finding; see violationFlag for what the supplier reported.
- epaSystems lists the public water systems that report serving this community's ZIP codes (EPA UCMR 5 ZIP list) with their EPA SDWIS violation counts. Counts are compliance events, not contaminant levels.
- publicWaterCoverage: share (0-1) of the community's land inside a public water system service area, from the NYS DOH boundaries EPA publishes; >=0.9 is shown as public water, <=0.1 as private wells, between as mixed.
- areaAssignment: 'inferred' means the SCWA distribution area was taken from neighboring mapped communities, not read from SCWA's map; confirm with SCWA's address lookup.
- dataTier: 'report' = rows from the supplier's annual water quality report; 'epa' = EPA-reported lead and PFAS sampling results so far; 'none' = no public supplier mapped (private wells).
- peakAboveLimit marks a contaminant whose highest single sample was above the limit even though its average was not. Compliance is judged on averages; peaks show what some homes may have received at times.
- Units: µg/L = micrograms per liter = parts per billion; mg/L = milligrams per liter = parts per million. ND = not detected.

## What this means for treatment

For West Hempstead, the numbers point first to whole-house carbon filtration: chlorine residual 1.65 mg/L.

- **Whole-House Carbon Filtration** (recommended): Chlorine residual 1.65 mg/L. Free chlorine averaged 1.65 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 0.75 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk.
- **Under-Sink Reverse Osmosis** (worth considering): Drinking-water polish. PFOA/PFOS reached 3.19 ng/L (ppt) in at least one sample — under New York's 10 ppt limit. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 27.3 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. The supplier's 90th-percentile lead result was 0.0011 mg/L (1 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.
- **Private Well Treatment** (worth considering): Private wells in part of the community. Part of West Hempstead is on private wells that none of these figures cover; a well needs its own test, and a well package is sized to what it finds.
- **Whole-House + Softener Combo** (not needed): Hardness 39 mg/L, about 2.3 grains per gallon. At 39 mg/L (2.3 gpg) the water is soft. A softener is not needed.

## Test your own water

A utility report describes the supply, not your tap, and does not cover private wells. Fieldstone Water Co. offers a free in-home water test across Long Island: call 516-43WATER (516-439-2837) or book at https://www.fieldstonewater.com/free-water-test.

---
Compilation © Fieldstone Water Co., licensed CC BY 4.0 (the underlying public records are not ours to copyright): reuse with attribution and a link to https://www.fieldstonewater.com/water/west-hempstead, keeping each figure's source citation. Text and explainers all rights reserved. https://www.fieldstonewater.com/terms#data-license