Suffolk County · Public water, some private wells (Inc. Village of Greenport)
Water Quality in Greenport, NY — What’s In Your Water
Greenport's water is supplied by Inc. Village of Greenport. The most recent published results show Copper at 0.42 mg/L, Barium at 0.023 mg/L. Every figure below is shown against its NY or EPA limit and cited to its source.
Reported contaminants
Greenport water, by the numbers
ND means not detected. Units: µg/L is micrograms per liter (parts per billion); ng/L is nanograms per liter (parts per trillion); mg/L is milligrams per liter (parts per million). Status uses the words below, near, exceeds, or trace — not color alone.
Source: Inc. Village of Greenport 2025 Annual Water Quality Report (opens in a new tab)
| Substance | Detected level | Limit | Status |
|---|---|---|---|
| Nitrate, metals & inorganics | |||
| Nitrate (about this substance) | 4.3 mg/L | 10EPA MCL | Below limit |
| Odor (about this substance) | 1.0 Units | 3NYS secondary standard | Below limit |
| Copper (about this substance) | 0.42 mg/L(90th percentile)Range 0.029–0.67 | 1.3EPA action level | Below limit |
| Chloride (about this substance) | 65.7 mg/L | 250NYS secondary standard | Below limit |
| Sulfate (about this substance) | 35.3 mg/L | 250NYS secondary standard | Below limit |
| Lead (about this substance) | ND µg/L(90th percentile)Range ND–1.2 | 15EPA action level | Trace — detected in some samples |
| Zinc (about this substance) | 0.10 µg/L | 5NYS secondary standard | Below limit |
| Barium (about this substance) | 0.023 mg/L | 2.0EPA MCL | Below limit |
| Iron (about this substance) | 0.037 mg/L | 300NYS secondary standard | Below limit |
| Sodium (about this substance) | 50.6 mg/L | No regulatory limit | — |
| Nickel (about this substance) | 0.041 mg/L | No regulatory limit | — |
| Specific conductance (about this substance) | 505 umhos/cm | No regulatory limit | — |
| Disinfection byproducts | |||
| Total Trihalomethanes (about this substance) | 4.6 µg/L | 80EPA MCL | Below limit |
| Dibromoacetic Acid (about this substance) | 2.1 µg/L | 60EPA MCL | Below limit |
| Total Haloacetic Acids (about this substance) | 2.1 µg/L | 60EPA MCL | Below limit |
| Dibromochloromethane (about this substance) | 1.5 µg/L | 80EPA MCL | Below limit |
| Bromoform (about this substance) | 1.3 µg/L | 80EPA MCL | Below limit |
| Bromodichloromethane (about this substance) | 0.96 µg/L | 80EPA MCL | Below limit |
| Chloroform (about this substance) | 0.85 µg/L | 80EPA MCL | Below limit |
Water characteristics
| Substance | Detected level | Limit | Status |
|---|---|---|---|
| Free Chlorine (about this substance) | 0.93 mg/LRange 0.42–0.93 | 4.0EPA MRDL | Below limit |
| pH (about this substance) | 7.5 UnitsRange 6.75–7.5 | No regulatory limit | — |
| Calcium hardness (about this substance) | 77.2 mg/L | No regulatory limit | — |
| Hardness (total) (about this substance) | 111.0 mg/L | No regulatory limit | — |
Status reflects the average of all samples. Individual readings may be higher; see range.
Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. The report carries 1 notice: NOTICE OF VIOLATION (monitoring): 'During the period between June and September 2025, we did not monitor or test the required Tier 1 sites for Lead & Copper in the distribution system, and therefore cannot be sure of the quality of your drinking water during that time.' What should I do? 'There is nothing you need to do at this time.' What does this mean? 'This is not an immediate risk.' What is being done? 'The missed samples will be collected in 2026.' About 50% of Greenport's land lies inside a public water service area (Greenport Water District and others), per the NYS Department of Health boundaries EPA publishes; the rest is on private wells. These results apply only to public water.
Your water district
Who supplies Greenport’s water
Inc. Village of Greenport
EPA compliance
Federal violation record for Greenport’s suppliers
The annual report above lists what was found in the water. EPA’s compliance database records whether each supplier met its testing, treatment, and reporting obligations.
- Suffolk County Water Authority
EPA ID NY5110526 · serves about 1,100,000 people
- Violations 2022–2026
- 3
- Health-based
- 0
- Last violation
- 2025
Compliance counts are EPA Safe Drinking Water Information System records pulled directly from EPA. Most violations are monitoring or reporting lapses, not unsafe water; health-based violations (a contaminant limit, disinfectant level, or treatment technique) are counted separately. A system listed for a ZIP code may serve only part of it.
What the numbers mean
Greenport is served largely by SCWA, with private wells mixed in toward its edges. Western and central Suffolk carry Long Island's signature groundwater story — trace 1,4-dioxane and PFAS from historic land use, plus nitrate loading from lawns and septic systems. SCWA treats for these at its wellfields, but a point-of-entry system gives you a second barrier and covers any private-well portion of the neighborhood.
What this means for filtration
Matching Greenport’s water to a system
For Greenport, the numbers point first to whole-house carbon filtration: chlorine residual 0.93 mg/L.
- Recommended
Whole-House Carbon Filtration
Chlorine residual 0.93 mg/L
Free chlorine averaged 0.93 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 0.96 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk.
Explore Whole-House Carbon Filtration - Worth considering
Under-Sink Reverse Osmosis
Drinking-water polish
Nitrate averaged 4.3 mg/L (limit 10), moderate but present; reverse osmosis reduces it at the tap. Sodium averaged 50.6 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets.
Explore Under-Sink Reverse Osmosis - Worth considering
Whole-House + Softener Combo
Hardness 111 mg/L, about 6.5 grains per gallon
At 111 mg/L (6.5 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity.
Explore Whole-House + Softener Combo - Worth considering
Private Well Treatment
Private wells in part of the community
Part of Greenport is on private wells that none of these figures cover; a well needs its own test, and a well package is sized to what it finds.
Explore Private Well Treatment
Questions
Greenport water FAQ
Nearby Suffolk County towns
Free in-home test
See what’s really in your Greenport water.
Published reports cover the public supply — a free in-home test measures your taps (and your well, if you have one), then we walk you through the results.