Suffolk County · Public water (SCWA — Huntington distribution area)
Water Quality in Huntington, NY — What’s In Your Water
Huntington is a split-service town. The village, harbor, and Halesite area are served by Suffolk County Water Authority Distribution Area 7; South Huntington, Huntington Station, Greenlawn, and Dix Hills have their own water districts and are not covered by the numbers on this page. In 2025, SCWA's Area 7 tests found nitrate averaging 7.7 mg/L with samples between 5.2 and 8.3 against a limit of 10 — the highest nitrate average of any SCWA area we track — alongside trace-level 1,4-dioxane (up to 0.26 µg/L against a 1.0 limit) and PFAS (up to 3 parts per trillion against a 10 ppt limit). Every figure below is shown against its New York or EPA limit and cited to the source report. Check your water bill to confirm which district serves you.
Reported contaminants
Huntington water, by the numbers
These are the results for the whole SCWA distribution area.
ND means not detected. Units: µg/L is micrograms per liter (parts per billion); ng/L is nanograms per liter (parts per trillion); mg/L is milligrams per liter (parts per million). Status uses the words below, near, exceeds, or trace — not color alone.
Source: Suffolk County Water Authority 2026 Drinking Water Quality Report (2025 data) (opens in a new tab)
Water characteristics
| Substance | Detected level | Limit | Status |
|---|---|---|---|
| Sodium Cyclamate (about this substance) | ND µg/L | 50NYS MCL (unspecified organic contaminant) | Not detected |
Status reflects the average of all samples. Individual readings may be higher; see range.
Values are ranges/averages across all wells feeding each distribution area at the entry point. A home near an area boundary may receive water from the adjacent area. South Huntington WD, Greenlawn WD, and Dix Hills WD also serve parts of 11743 — check your water bill to confirm your district. SCWA area 7 sample counts are small for some inorganics (n=4–26). 100% of Huntington's land lies inside a public water service area (Suffolk County Water Authority and others), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.
Your water district
Who supplies Huntington’s water
Check your water bill to confirm your district. More than one utility serves this town — the name on your bill is the one that matches your service.
Suffolk County Water Authority
Much of Huntington; check your water bill.
South Huntington Water District
Huntington Station, Melville, South Huntington, parts of Huntington and Cold Spring Harbor.
Greenlawn Water District
Greenlawn and East Northport areas.
EPA compliance
Federal violation record for Huntington’s suppliers
The annual report above lists what was found in the water. EPA’s compliance database records whether each supplier met its testing, treatment, and reporting obligations.
- Suffolk County Water Authority
EPA ID NY5110526 · serves about 1,100,000 people
- Violations 2022–2026
- 3
- Health-based
- 0
- Last violation
- 2025
- South Huntington Water District
EPA ID NY5103263 · serves about 81,760 people
- Violations 2022–2026
- 39
- Health-based
- 0
- Last violation
- 2025
- Greenlawn Water District
EPA ID NY5103271 · serves about 42,000 people
- Violations 2022–2026
- 78
- Health-based
- 0
- Last violation
- 2026
Compliance counts are EPA Safe Drinking Water Information System records pulled directly from EPA. Most violations are monitoring or reporting lapses, not unsafe water; health-based violations (a contaminant limit, disinfectant level, or treatment technique) are counted separately. A system listed for a ZIP code may serve only part of it.
What the numbers mean
Nitrate is the headline
Nitrate is the headline. Area 7 averaged 7.7 mg/L in 2025, with every sample between 5.2 and 8.3. That is three-quarters of the federal limit, and there is no "some wells are low" story here — the floor is 5.2. This is the highest nitrate average of the SCWA areas we track. Nitrate comes from fertilizer and septic systems; north-shore Huntington's older housing stock and heavy lawn coverage are the likely reasons. It is not removed by carbon filtration. Reverse osmosis at the kitchen tap is the direct fix.
Everything else was trace or clean. 1,4-dioxane averaged 0.07 µg/L with a high of 0.26 against a 1.0 limit. PFOA and PFOS peaked at 2 and 3 ppt against a 10 ppt limit. Iron, manganese, PCE, and TCE were not detected. Chloride averaged 28 mg/L, low for a harbor-adjacent area.
Sample counts are small. SCWA ran only 4 to 26 tests for most inorganics in Area 7 in 2025, versus hundreds in larger areas. The nitrate number is based on 25 samples. Treat these as a reliable snapshot rather than a deep dataset.
Hardness is on the higher side for Suffolk. At 100.5 mg/L average (about 5.9 grains per gallon), Area 7 water is harder than the Three Village area and closer to Nassau levels. A softener is a reasonable addition here.
If you're not on SCWA, none of this applies to you. South Huntington Water District, Greenlawn Water District, and Dix Hills Water District each publish their own annual reports with their own numbers. Your water bill tells you which one you're on.
What this means for filtration
Matching Huntington’s water to a system
For Huntington, the numbers point first to under-sink reverse osmosis and whole-house carbon filtration: dissolved contaminants close to their limits.
- Recommended
Under-Sink Reverse Osmosis
Dissolved contaminants close to their limits
Nitrate averaged 7.69 mg/L with samples up to 8.32 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. PFOA/PFOS reached 3 ng/L (ppt) in at least one sample — under New York's 10 ppt limit. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Perchlorate was detected up to 1.31 µg/L (limit 18). Hexavalent chromium averaged 1.69 µg/L; there is no federal limit for chromium-6 itself, and reverse osmosis reduces it. The supplier's 90th-percentile lead result was 0.00125 mg/L (1 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.
Explore Under-Sink Reverse Osmosis - Recommended
Whole-House Carbon Filtration
Solvent traces and chlorine in the supply
Free chlorine averaged 0.92 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 3.82 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk. Solvent traces were detected: 1,1,1-Trichloroethane up to 0.37 µg/L (limit 5 each). Whether a whole-house carbon model reduces those solvents is on that model's data sheet.
Explore Whole-House Carbon Filtration - Worth considering
Whole-House + Softener Combo
Hardness 101 mg/L, about 5.9 grains per gallon
At 101 mg/L (5.9 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity.
Explore Whole-House + Softener Combo
Questions
Huntington water FAQ
Nearby Suffolk County towns
Free in-home test
See what’s really in your Huntington water.
Published reports cover the public supply — a free in-home test measures your taps (and your well, if you have one), then we walk you through the results.