Skip to content
Fieldstone Water Co.

Suffolk County · Public water (Riverhead Water District)

Water Quality in Riverhead, NY — What’s In Your Water

Riverhead's water is supplied by Riverhead Water District. The most recent published results show Iron at 0.92 mg/L (above the limit), Lead at 2.0 µg/L. Every figure below is shown against its NY or EPA limit and cited to its source.

Reported contaminants

Riverhead water, by the numbers

Data from Riverhead Water District 2025 Water Quality Report · Verified 2026-11-11

ND means not detected. Units: µg/L is micrograms per liter (parts per billion); ng/L is nanograms per liter (parts per trillion); mg/L is milligrams per liter (parts per million). Status uses the words below, near, exceeds, or trace — not color alone.

Contaminants reported in Riverhead, Suffolk County drinking water, with detected level, regulatory limit, and status.
SubstanceDetected levelLimitStatusSource
PFAS
PFOS (about this substance)6.2 ng/LRaw-water maximum 7.23 ng/LTreated sample at Well 5-1: not detected. The report lists this chemical among contaminants undetected in the water supply.From the report's supplemental well table: Samples were taken from raw water at Well 5-1 (Raw Well), not the distribution system (maximum 7.23 ng/L, average 6.2 ng/L, 3 samples); the treated sample at Well 5-1 was not detected, and the report lists PFOS among contaminants undetected in the water supply.10NYS MCLRaw source water, before treatmentRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
PFOA (about this substance)5.63 ng/LRaw-water maximum 5.97 ng/LTreated sample at Well 5-1: not detected. The report lists this chemical among contaminants undetected in the water supply.From the report's supplemental well table: Samples were taken from raw water at Well 5-1 (Raw Well), not the distribution system (maximum 5.97 ng/L, average 5.63 ng/L, 3 samples); the treated sample at Well 5-1 was not detected, and the report lists PFOA among contaminants undetected in the water supply.10NYS MCLRaw source water, before treatmentRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
PFBA (about this substance)2.51 ng/LRange ND–2.51No regulatory limit—Riverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Tested for and not detected (4): HFPO-DA (about this substance), PFHxS (about this substance), PFNA (about this substance), PFBS (about this substance)
Nitrate, metals & inorganics
Combined Radium 226/228 (about this substance)22.8 pCi/LRange 17.5–22.85EPA MCLPrinted figure disputed — see noteRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Iron (about this substance)0.92 mg/LRange ND–0.920.3NYS secondary standardExceeds limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Manganese (about this substance)0.28 mg/LRange ND–0.280.3NYS secondary standardNear limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Odor (about this substance)2.0 UnitsRange ND–2.03.0NYS secondary standardBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Perchlorate (about this substance)11.2 µg/LRange ND–11.218EPA action levelBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Arsenic (about this substance)5.9 µg/LRange ND–5.910EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Nitrate (about this substance)5.8 mg/LRange ND–5.810EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Cyanide (about this substance)18.5 µg/LRange ND–18.550EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
1,2,3-Trichloropropane (about this substance)1.7 µg/LRange ND–1.75.0EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Sulfate (about this substance)79.8 mg/LRange ND–79.8250NYS secondary standardBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Chloride (about this substance)40.8 mg/LRange 5.3–40.8250NYS secondary standardBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Zinc (about this substance)0.75 mg/LRange ND–0.755NYS secondary standardBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Gross alpha (about this substance)0.721 pCi/LRange ND–0.72115EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Barium (about this substance)0.069 mg/LRange ND–0.0692.0EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Gross beta (about this substance)1.41 pCi/LRange 0.383–1.4150EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Metolachlor (about this substance)0.17 µg/LRange ND–0.1750EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Nickel (about this substance)0.0014 mg/LRange ND–0.0014100EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Calcium hardness (about this substance)118.0 mg/LRange 8.0–118.0No regulatory limit—Riverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Specific conductance (about this substance)428.0 umhos/cmRange 50.7–428.0No regulatory limit—Riverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Ammonia (as N) (about this substance)0.16 mg/LRange ND–0.16No regulatory limit—Riverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Sodium (about this substance)21.8 mg/LRange 4.6–21.8No regulatory limit—Riverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Lead & copper
Copper (about this substance)0.25 mg/L(90th percentile)Range 0.27–0.61.3EPA action levelBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Lead (about this substance)2.0 µg/L(90th percentile)Range ND–10.315EPA action levelBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Disinfection byproducts
Total Trihalomethanes (about this substance)6.6 µg/LRange ND–6.680EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Bromodichloromethane (about this substance)2.5 µg/LRange ND–2.580EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Dibromochloromethane (about this substance)2.1 µg/LRange ND–2.180EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Chloroform (about this substance)1.9 µg/LRange ND–1.980EPA MCLBelow limitRiverhead Water District 2025 Annual Water Quality Report (opens in a new tab)
Chlorate (about this substance)22.8 µg/LRange 17.5–22.8No regulatory limit—Riverhead Water District 2025 Annual Water Quality Report (opens in a new tab)

Where the report prints only a range, status reflects the high end of that range; where it prints an average, status reflects the average.

Where the report prints both an average and a range, the status column here is judged on the average; where it prints a maximum or a 90th-percentile result, that figure is used. The report carries 1 notice: Iron row marked Violation 'Yes' (ND - 0.92 mg/l vs MCL = 0.3, sample date 12/12/25). Page 2: 'We are pleased to report that our drinking water is safe and meets all Federal and State requirements with the exception of iron.' Footnote (4) explains iron health effects and that the District adds a sequestering agent. No formal Notice of Violation text is printed. 99% of Riverhead's land lies inside a public water service area (Riverhead Water District), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

Your water district

Who supplies Riverhead’s water

EPA compliance

Federal violation record for Riverhead’s suppliers

The annual report above lists what was found in the water. EPA’s compliance database records whether each supplier met its testing, treatment, and reporting obligations.

Compliance counts are EPA Safe Drinking Water Information System records pulled directly from EPA. Most violations are monitoring or reporting lapses, not unsafe water; health-based violations (a contaminant limit, disinfectant level, or treatment technique) are counted separately. A system listed for a ZIP code may serve only part of it.

What the numbers mean

Riverhead is served largely by SCWA, with private wells mixed in toward its edges. Western and central Suffolk carry Long Island's signature groundwater story — trace 1,4-dioxane and PFAS from historic land use, plus nitrate loading from lawns and septic systems. SCWA treats for these at its wellfields, but a point-of-entry system gives you a second barrier and covers any private-well portion of the neighborhood.

What this means for filtration

Matching Riverhead’s water to a system

For Riverhead, the numbers point first to under-sink reverse osmosis: dissolved contaminants close to their limits.

  • Recommended

    Under-Sink Reverse Osmosis

    Dissolved contaminants close to their limits

    Nitrate averaged 5.8 mg/L with samples up to 5.8 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. PFOA/PFOS reached 7.23 ng/L (ppt) in at least one sample — under New York's 10 ppt limit but at or above the 4.0 ppt federal MCL, with federal compliance due April 26, 2029. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Sodium averaged 21.8 mg/L, above the 20 mg/L level New York flags for sodium-restricted diets. Perchlorate was detected up to 11.2 µg/L (limit 18). The supplier's 90th-percentile lead result was 0.002 mg/L (2 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.

    Explore Under-Sink Reverse Osmosis
  • Worth considering

    Whole-House Carbon Filtration

    Chlorine and taste at every tap

    Chlorination by-products (trihalomethanes) reached 2.5 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk.

    Explore Whole-House Carbon Filtration

Questions

Riverhead water FAQ

Free in-home test

See what’s really in your Riverhead water.

Published reports cover the public supply — a free in-home test measures your taps (and your well, if you have one), then we walk you through the results.