Cold Spring Harbor's water is supplied by the Suffolk County Water Authority (SCWA) — Distribution Area 6. The most recent published results show Acesulfame-K at 0.05 µg/L, Chlorate at 0.07 mg/L. Every figure below is shown against its NY or EPA limit and cited to its source.

Reported contaminants

Cold Spring Harbor water, by the numbers

Data: SCWA 2026 Drinking Water Quality Report (2025 data) · Verified 2026-09-14

These are the results for the whole SCWA distribution area. See every community in Area 6

ND means not detected. Units: µg/L is micrograms per liter (parts per billion); ng/L is nanograms per liter (parts per trillion); mg/L is milligrams per liter (parts per million). Status uses the words below, near, exceeds, or trace — not color alone.

Source: Suffolk County Water Authority 2026 Drinking Water Quality Report (2025 data) (opens in a new tab)

Contaminants reported in Cold Spring Harbor, Suffolk County drinking water, with detected level, regulatory limit, and status.
SubstanceDetected levelLimitStatus
PFAS
PFOA (about this substance)ND ng/LRange ND–210NYS MCLTrace — detected in some samples
PFPeA (about this substance)ND ng/LRange ND–250000NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Tested for and not detected (9): PFOS (about this substance), 6:2 FTS (about this substance), PFBS (about this substance), PFBA (about this substance), PFHpA (about this substance), PFHxS (about this substance), PFHxA (about this substance), PFNA (about this substance), PFPeS (about this substance)
Industrial solvents & 1,4-dioxane
1,4-Dioxane (about this substance)0.40 µg/LRange ND–1.20Highest single result 1.20 µg/L. The report's violation column is No.1NYS MCLNo violation reported
cis-1,2-Dichloroethene (about this substance)ND µg/LRange ND–1.755NYS MCL (principal organic contaminant)Trace — detected in some samples
Trichloroethene (TCE) (about this substance)ND µg/LRange ND–0.685NYS MCL (principal organic contaminant)Trace — detected in some samples
1,1-Dichloroethene (about this substance)ND µg/LRange ND–0.625NYS MCL (principal organic contaminant)Trace — detected in some samples
1,1,1-Trichloroethane (about this substance)ND µg/LRange ND–0.515NYS MCL (principal organic contaminant)Trace — detected in some samples
Tetrachloroethene (PCE) (about this substance)0.26 µg/LRange ND–1.995NYS MCL (principal organic contaminant)Below limit
Nitrate, metals & inorganics
Nitrate (about this substance)6.03 mg/LRange 0.25–8.9410EPA MCLBelow limit
Iron (about this substance)ND µg/LRange ND–77300NYS secondary standardTrace — detected in some samples
Radium-228 (about this substance)1.18 pCi/LRange ND–1.845EPA MCLBelow limit
1,1,2-Trichlorotrifluoroethane (about this substance)ND µg/LRange ND–0.905NYS MCL (principal organic contaminant)Trace — detected in some samples
Gross alpha (about this substance)ND pCi/LRange ND–1.7915EPA MCLTrace — detected in some samples
1,1-Dichlorethane (about this substance)0.52 µg/LRange ND–2.535NYS MCL (principal organic contaminant)Below limit
Gross beta (about this substance)ND pCi/LRange ND–4.4950EPA MCLTrace — detected in some samples
Turbidity (about this substance)0.44 NTURange ND–1.885EPA MCLBelow limit
Chloride (about this substance)21.9 mg/LRange 7.9–32.3250NYS secondary standardBelow limit
1,2-Dichloropropane (about this substance)ND µg/LRange ND–0.375NYS MCL (principal organic contaminant)Trace — detected in some samples
Perchlorate (about this substance)0.91 µg/LRange ND–3.1618NYS MCLBelow limit
Sulfate (about this substance)12.4 mg/LRange ND–25.3250NYS secondary standardBelow limit
Copper (about this substance)ND mg/LRange ND–0.041.3EPA action levelTrace — detected in some samples
Tetrachloroterephthalic Acid (about this substance)1.00 µg/LRange ND–4.2750NYS MCL (unspecified organic contaminant)Below limit
Chromium (total) (about this substance)1.3 µg/LRange ND–9.2100EPA MCLBelow limit
Hexavalent Chromium (about this substance)1.15 µg/LRange ND–9.16100EPA MCLBelow limit
Barium (about this substance)0.02 mg/LRange ND–0.062EPA MCLBelow limit
Zinc (about this substance)ND mg/LRange ND–0.035NYS secondary standardTrace — detected in some samples
Acesulfame-K (about this substance)0.05 µg/LRange ND–0.5150NYS MCL (unspecified organic contaminant)Below limit
Alkalinity (about this substance)54.7 mg/LRange ND–95.2No regulatory limit—
Aluminum (about this substance)0.03 mg/LRange ND–0.09No regulatory limit—
Bromide (about this substance)ND µg/LRange ND–78.4No regulatory limitTrace — detected in some samples
Calcium (about this substance)23.5 mg/LRange 7.3–45.9No regulatory limit—
CO2, calculated (about this substance)7.3 mg/LRange 1.7–26.9No regulatory limit—
Cobalt (about this substance)ND µg/LRange ND–0.7No regulatory limitTrace — detected in some samples
Hardness (total) (about this substance)78.3 mg/LRange 24.8–148.4No regulatory limit—
Lithium (about this substance)ND µg/LRange ND–2.1No regulatory limitTrace — detected in some samples
Magnesium (about this substance)4.78 mg/LRange 1.59–8.32No regulatory limit—
Nickel (about this substance)0.7 µg/LRange ND–1.7No regulatory limit—
pH (about this substance)7.3 pH UnitsRange 6.7–8.2No regulatory limit—
pH, field (about this substance)7.4 pH UnitsRange 7.0–8.2No regulatory limit—
Potassium (about this substance)1.07 mg/LRange 0.60–1.41No regulatory limit—
Silicon (about this substance)6.9 mg/LRange 4.7–9.7No regulatory limit—
Sodium (about this substance)11.2 mg/LRange 6.1–17.7No regulatory limit—
Specific conductance (about this substance)227 umho/cmRange 85–407No regulatory limit—
Strontium (about this substance)0.077 mg/LRange 0.025–0.136No regulatory limit—
Radon-222 (about this substance)183 pCi/LRange 130–235No regulatory limit—
Tested for and not detected (46): Carbamazepine (about this substance), Dilantin (about this substance), 5-(4-Hydroxyphenyl)-5-Phenylhydantoin (about this substance), Ibuprofen (about this substance), Imidacloprid (about this substance), Lamotrigine (about this substance), Meprobamate (about this substance), Phenobarbital (about this substance), Primidone (about this substance), Saccharin (about this substance), Stevioside (about this substance), Sucralose (about this substance), Ammonia (as N) (about this substance), Arsenic (about this substance), Boron (about this substance), Color (about this substance), Fluoride (about this substance), Manganese (about this substance), Molybdenum (about this substance), Nitrite (about this substance), Phosphate, total (about this substance), Titanium (about this substance), Total Organic Carbon (TOC) (about this substance), Uranium (about this substance), Vanadium (about this substance), Alachlor ESA (about this substance), Alachlor OA (about this substance), Chlordane (about this substance), Diethyltoluamide (DEET) (about this substance), Metalaxyl (about this substance), Metolachlor (about this substance), Metolachlor OA (about this substance), Chlorobenzene (about this substance), Chlorodifluoromethane (about this substance), Chloromethane (about this substance), Dichlorodifluoromethane (about this substance), Ethyl Benzene (about this substance), Methylene Chloride (about this substance), MTBE (about this substance), o-Xylene (about this substance), p,m-Xylene (about this substance), Tetrahydrofuran (about this substance), 1,2,4-Trichlorobenzene (about this substance), Trichlorofluoromethane (about this substance), 1,2,3-Trichloropropane (about this substance), Radium-226 (about this substance)
Lead & copper
Copper (tap samples) (about this substance)0.377 mg/L(90th percentile)Range 0.022–0.6201.3EPA action levelBelow limit
Lead (about this substance)1.25 µg/L(90th percentile)Range ND–6.4715EPA action levelBelow limit
Disinfection byproducts
Free Chlorine (about this substance)1.00 mg/LRange 0.31–1.504EPA MRDLBelow limit
Bromodichloromethane (about this substance)ND µg/LRange ND–5.2780EPA MCLTrace — detected in some samples
Dibromochloromethane (about this substance)ND µg/LRange ND–4.6280EPA MCLTrace — detected in some samples
Chloroform (about this substance)ND µg/LRange ND–4.3580EPA MCLTrace — detected in some samples
Bromochloroacetic Acid (about this substance)ND µg/LRange ND–1.3550EPA MCLTrace — detected in some samples
Dichloroacetic Acid (about this substance)ND µg/LRange ND–1.5860EPA MCLTrace — detected in some samples
Bromoform (about this substance)ND µg/LRange ND–2.0280EPA MCLTrace — detected in some samples
Dibromoacetic Acid (about this substance)ND µg/LRange ND–0.6960EPA MCLTrace — detected in some samples
Chlorate (about this substance)0.07 mg/LRange 0.04–0.11No regulatory limit—
Bromodichloroacetic Acid (about this substance)ND µg/L50EPA MCLNot detected
Monochloroacetic Acid (about this substance)ND µg/L60EPA MCLNot detected
Trichloroacetic Acid (about this substance)ND µg/L60EPA MCLNot detected

Water characteristics

Water characteristics reported in Cold Spring Harbor, Suffolk County drinking water.
SubstanceDetected levelLimitStatus
Sodium Cyclamate (about this substance)ND µg/L50NYS MCL (unspecified organic contaminant)Not detected

Status reflects the average of all samples. Individual readings may be higher; see range.

Values are ranges/averages across all wells feeding each distribution area at the entry point. A home near an area boundary may receive water from the adjacent area. Some homes here draw from private wells. These results do not apply to well water. Area assignment is read from SCWA's distribution-area map. Confirm your address with SCWA's See My Water Quality lookup (https://www.scwa.com/mywaterquality/ (opens in a new tab)). 99% of Cold Spring Harbor's land lies inside a public water service area (Suffolk County Water Authority and others), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

Your water district

Who supplies Cold Spring Harbor’s water

EPA compliance

Federal violation record for Cold Spring Harbor’s suppliers

The annual report above lists what was found in the water. EPA’s compliance database records whether each supplier met its testing, treatment, and reporting obligations.

Compliance counts are EPA Safe Drinking Water Information System records pulled directly from EPA. Most violations are monitoring or reporting lapses, not unsafe water; health-based violations (a contaminant limit, disinfectant level, or treatment technique) are counted separately. A system listed for a ZIP code may serve only part of it.

What the numbers mean

Cold Spring Harbor is served largely by SCWA, with private wells mixed in toward its edges. Western and central Suffolk carry Long Island's signature groundwater story — trace 1,4-dioxane and PFAS from historic land use, plus nitrate loading from lawns and septic systems. SCWA treats for these at its wellfields, but a point-of-entry system gives you a second barrier and covers any private-well portion of the neighborhood.

What this means for filtration

Matching Cold Spring Harbor’s water to a system

For Cold Spring Harbor, the numbers point first to under-sink reverse osmosis and whole-house carbon filtration: dissolved contaminants close to their limits.

  • Recommended

    Under-Sink Reverse Osmosis

    Dissolved contaminants close to their limits

    Nitrate averaged 6.03 mg/L with samples up to 8.94 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. PFOA/PFOS reached 2 ng/L (ppt) in at least one sample — under New York's 10 ppt limit. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Perchlorate was detected up to 3.16 µg/L (limit 18). Hexavalent chromium averaged 1.15 µg/L; there is no federal limit for chromium-6 itself, and reverse osmosis reduces it. The supplier's 90th-percentile lead result was 0.00125 mg/L (1 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.

    Explore Under-Sink Reverse Osmosis
  • Recommended

    Whole-House Carbon Filtration

    Solvent traces and chlorine in the supply

    Free chlorine averaged 1 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 5.27 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk. Solvent traces were detected: Trichloroethene (TCE) up to 0.68 µg/L, Tetrachloroethene (PCE) up to 1.99 µg/L, 1,1,1-Trichloroethane up to 0.51 µg/L, cis-1,2-Dichloroethene up to 1.75 µg/L (limit 5 each). Whether a whole-house carbon model reduces those solvents is on that model's data sheet.

    Explore Whole-House Carbon Filtration
  • Worth considering

    Whole-House + Softener Combo

    Hardness 78.3 mg/L, about 4.6 grains per gallon

    At 78.3 mg/L (4.6 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity; some homes near the top of the 148 mg/L range will notice scale.