Water Quality in Ronkonkoma, NY — What’s In Your Water

Ronkonkoma's water is supplied by the Suffolk County Water Authority (SCWA) — Distribution Area 12. The most recent published results show PFPeA at 2 ng/L, Acesulfame-K at 0.08 µg/L. Every figure below is shown against its NY or EPA limit and cited to its source.

Reported contaminants

Ronkonkoma water, by the numbers

Data: SCWA 2026 Drinking Water Quality Report (2025 data) · Verified 2026-09-14

These are the results for the whole SCWA distribution area. See every community in Area 12

ND means not detected. Units: µg/L is micrograms per liter (parts per billion); ng/L is nanograms per liter (parts per trillion); mg/L is milligrams per liter (parts per million). Status uses the words below, near, exceeds, or trace — not color alone.

Source: Suffolk County Water Authority 2026 Drinking Water Quality Report (2025 data) (opens in a new tab)

Contaminants reported in Ronkonkoma, Suffolk County drinking water, with detected level, regulatory limit, and status.
SubstanceDetected levelLimitStatus
PFAS
PFOS (about this substance)ND ng/LRange ND–13Highest single result 13 ng/L. The report's violation column is No.10NYS MCLNo violation reported
PFOA (about this substance)ND ng/LRange ND–710NYS MCLTrace — detected in some samples
PFHxS (about this substance)ND ng/LRange ND–1250000NYS MCL (unspecified organic contaminant)Trace — detected in some samples
PFHxA (about this substance)ND ng/LRange ND–1050000NYS MCL (unspecified organic contaminant)Trace — detected in some samples
PFBA (about this substance)ND ng/LRange ND–750000NYS MCL (unspecified organic contaminant)Trace — detected in some samples
PFBS (about this substance)ND ng/LRange ND–550000NYS MCL (unspecified organic contaminant)Trace — detected in some samples
PFHpA (about this substance)ND ng/LRange ND–450000NYS MCL (unspecified organic contaminant)Trace — detected in some samples
PFPeA (about this substance)2 ng/LRange ND–1850000NYS MCL (unspecified organic contaminant)Below limit
6:2 FTS (about this substance)ND ng/L50000NYS MCL (unspecified organic contaminant)Not detected
PFNA (about this substance)ND ng/L50000NYS MCL (unspecified organic contaminant)Not detected
PFPeS (about this substance)ND ng/L50000NYS MCL (unspecified organic contaminant)Not detected
Industrial solvents & 1,4-dioxane
Tetrachloroethene (PCE) (about this substance)ND µg/LRange ND–2.545NYS MCL (principal organic contaminant)Trace — detected in some samples
1,4-Dioxane (about this substance)0.17 µg/LRange ND–0.991NYS MCLBelow limit
1,1-Dichloroethene (about this substance)ND µg/LRange ND–0.845NYS MCL (principal organic contaminant)Trace — detected in some samples
1,1,1-Trichloroethane (about this substance)ND µg/LRange ND–0.815NYS MCL (principal organic contaminant)Trace — detected in some samples
Trichloroethene (TCE) (about this substance)ND µg/LRange ND–0.725NYS MCL (principal organic contaminant)Trace — detected in some samples
cis-1,2-Dichloroethene (about this substance)ND µg/LRange ND–0.425NYS MCL (principal organic contaminant)Trace — detected in some samples
Nitrate, metals & inorganics
Color (about this substance)ND Color UnitsRange ND–1215NYS secondary standardTrace — detected in some samples
Dichlorodifluoromethane (about this substance)ND µg/LRange ND–3.375NYS MCL (principal organic contaminant)Trace — detected in some samples
1,1-Dichlorethane (about this substance)ND µg/LRange ND–2.985NYS MCL (principal organic contaminant)Trace — detected in some samples
Arsenic (about this substance)ND µg/LRange ND–4.610EPA MCLTrace — detected in some samples
Gross beta (about this substance)ND pCi/LRange ND–21.3050EPA MCLTrace — detected in some samples
Nitrate (about this substance)4.25 mg/LRange ND–9.2710EPA MCLBelow limit
Radium-228 (about this substance)ND pCi/LRange ND–1.565EPA MCLTrace — detected in some samples
Chlorodifluoromethane (about this substance)ND µg/LRange ND–1.555NYS MCL (principal organic contaminant)Trace — detected in some samples
Iron (about this substance)88 µg/LRange ND–850300NYS secondary standardExceeds limit
Gross alpha (about this substance)ND pCi/LRange ND–2.7815EPA MCLTrace — detected in some samples
Chloride (about this substance)40.3 mg/LRange 3.9–105.4250NYS secondary standardBelow limit
Copper (about this substance)ND mg/LRange ND–0.191.3EPA action levelTrace — detected in some samples
Turbidity (about this substance)0.57 NTURange ND–3.795EPA MCLBelow limit
Manganese (about this substance)25 µg/LRange ND–191300NYS secondary standardBelow limit
p,m-Xylene (about this substance)ND µg/LRange ND–0.405NYS MCL (principal organic contaminant)Trace — detected in some samples
o-Xylene (about this substance)ND µg/LRange ND–0.395NYS MCL (principal organic contaminant)Trace — detected in some samples
Tetrachloroterephthalic Acid (about this substance)ND µg/LRange ND–3.4250NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Chloromethane (about this substance)ND µg/LRange ND–0.345NYS MCL (principal organic contaminant)Trace — detected in some samples
MTBE (about this substance)ND µg/LRange ND–0.5610EPA MCLTrace — detected in some samples
1,1,2-Trichlorotrifluoroethane (about this substance)ND µg/LRange ND–0.285NYS MCL (principal organic contaminant)Trace — detected in some samples
Sulfate (about this substance)13.2 mg/LRange ND–30.2250NYS secondary standardBelow limit
Chlorobenzene (about this substance)ND µg/LRange ND–0.235NYS MCL (principal organic contaminant)Trace — detected in some samples
Barium (about this substance)ND mg/LRange ND–0.092EPA MCLTrace — detected in some samples
Perchlorate (about this substance)0.44 µg/LRange ND–2.9618NYS MCLBelow limit
Hexavalent Chromium (about this substance)0.68 µg/LRange ND–22.82100EPA MCLBelow limit
Chromium (total) (about this substance)0.6 µg/LRange ND–21.4100EPA MCLBelow limit
Diethyltoluamide (DEET) (about this substance)ND µg/LRange ND–0.2750NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Sucralose (about this substance)0.20 µg/LRange ND–2.3750NYS MCL (unspecified organic contaminant)Below limit
5-(4-Hydroxyphenyl)-5-Phenylhydantoin (about this substance)ND µg/LRange ND–0.1550NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Phenobarbital (about this substance)ND µg/LRange ND–0.1150NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Dilantin (about this substance)ND µg/LRange ND–0.0950NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Acesulfame-K (about this substance)0.08 µg/LRange ND–1.1850NYS MCL (unspecified organic contaminant)Below limit
Lamotrigine (about this substance)ND µg/LRange ND–0.0750NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Meprobamate (about this substance)ND µg/LRange ND–0.0750NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Ibuprofen (about this substance)ND µg/LRange ND–0.0650NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Saccharin (about this substance)ND µg/LRange ND–0.0650NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Stevioside (about this substance)ND µg/LRange ND–0.0550NYS MCL (unspecified organic contaminant)Trace — detected in some samples
Alkalinity (about this substance)57.9 mg/LRange ND–159.8No regulatory limit—
Aluminum (about this substance)0.03 mg/LRange ND–0.23No regulatory limit—
Ammonia (as N) (about this substance)ND mg/LRange ND–0.15No regulatory limitTrace — detected in some samples
Bromide (about this substance)ND µg/LRange ND–96.1No regulatory limitTrace — detected in some samples
Calcium (about this substance)22.0 mg/LRange 3.4–65.9No regulatory limit—
CO2, calculated (about this substance)6.6 mg/LRange 0.3–39.8No regulatory limit—
Cobalt (about this substance)ND µg/LRange ND–2.7No regulatory limitTrace — detected in some samples
Hardness (total) (about this substance)72.5 mg/LRange 11.3–198.2No regulatory limit—
Lithium (about this substance)ND µg/LRange ND–5.6No regulatory limitTrace — detected in some samples
Magnesium (about this substance)4.27 mg/LRange 0.34–19.17No regulatory limit—
Molybdenum (about this substance)ND µg/LRange ND–1.1No regulatory limitTrace — detected in some samples
Nickel (about this substance)0.7 µg/LRange ND–6.3No regulatory limit—
pH (about this substance)7.3 pH UnitsRange 6.5–8.9No regulatory limit—
pH, field (about this substance)7.4 pH UnitsRange 6.0–8.5No regulatory limit—
Phosphate, total (about this substance)0.62 mg/LRange ND–4.57No regulatory limit—
Potassium (about this substance)1.15 mg/LRange 0.21–3.46No regulatory limit—
Silicon (about this substance)6.5 mg/LRange 3.1–10.6No regulatory limit—
Sodium (about this substance)18.1 mg/LRange 3.2–62.4No regulatory limit—
Specific conductance (about this substance)252 umho/cmRange 30–630No regulatory limit—
Strontium (about this substance)0.058 mg/LRange ND–0.190No regulatory limit—
Titanium (about this substance)ND µg/LRange ND–10.1No regulatory limitTrace — detected in some samples
Total Organic Carbon (TOC) (about this substance)ND mg/LRange ND–0.7No regulatory limitTrace — detected in some samples
Vanadium (about this substance)ND µg/LRange ND–5.2No regulatory limitTrace — detected in some samples
Radon-222 (about this substance)ND pCi/LRange ND–139No regulatory limitTrace — detected in some samples
Tested for and not detected (22): Carbamazepine (about this substance), Imidacloprid (about this substance), Primidone (about this substance), Boron (about this substance), Fluoride (about this substance), Nitrite (about this substance), Uranium (about this substance), Zinc (about this substance), Alachlor ESA (about this substance), Alachlor OA (about this substance), Chlordane (about this substance), Metalaxyl (about this substance), Metolachlor (about this substance), Metolachlor OA (about this substance), 1,2-Dichloropropane (about this substance), Ethyl Benzene (about this substance), Methylene Chloride (about this substance), Tetrahydrofuran (about this substance), 1,2,4-Trichlorobenzene (about this substance), Trichlorofluoromethane (about this substance), 1,2,3-Trichloropropane (about this substance), Radium-226 (about this substance)
Lead & copper
Copper (tap samples) (about this substance)0.377 mg/L(90th percentile)Range 0.022–0.6201.3EPA action levelBelow limit
Lead (about this substance)1.25 µg/L(90th percentile)Range ND–6.4715EPA action levelBelow limit
Disinfection byproducts
Free Chlorine (about this substance)0.98 mg/LRange 0.27–1.594EPA MRDLBelow limit
Bromoform (about this substance)ND µg/LRange ND–3.8780EPA MCLTrace — detected in some samples
Dichloroacetic Acid (about this substance)ND µg/LRange ND–2.4960EPA MCLTrace — detected in some samples
Monochloroacetic Acid (about this substance)ND µg/LRange ND–2.4960EPA MCLTrace — detected in some samples
Bromochloroacetic Acid (about this substance)ND µg/LRange ND–1.8050EPA MCLTrace — detected in some samples
Dibromoacetic Acid (about this substance)ND µg/LRange ND–1.0260EPA MCLTrace — detected in some samples
Trichloroacetic Acid (about this substance)ND µg/LRange ND–0.8360EPA MCLTrace — detected in some samples
Chloroform (about this substance)0.43 µg/LRange ND–8.5380EPA MCLBelow limit
Bromodichloromethane (about this substance)0.26 µg/LRange ND–9.3280EPA MCLBelow limit
Dibromochloromethane (about this substance)0.26 µg/LRange ND–9.2880EPA MCLBelow limit
Chlorate (about this substance)0.10 mg/LRange ND–0.48No regulatory limit—
Bromodichloroacetic Acid (about this substance)ND µg/L50EPA MCLNot detected

Water characteristics

Water characteristics reported in Ronkonkoma, Suffolk County drinking water.
SubstanceDetected levelLimitStatus
Sodium Cyclamate (about this substance)ND µg/LRange ND–0.1650NYS MCL (unspecified organic contaminant)Trace — detected in some samples

Status reflects the average of all samples. Individual readings may be higher; see range.

Values are ranges/averages across all wells feeding each distribution area at the entry point. A home near an area boundary may receive water from the adjacent area. Area assignment is read from SCWA's distribution-area map. Confirm your address with SCWA's See My Water Quality lookup (https://www.scwa.com/mywaterquality/ (opens in a new tab)). 100% of Ronkonkoma's land lies inside a public water service area (Suffolk County Water Authority), per the NYS Department of Health boundaries EPA publishes. A service area is where mains run; a home inside it can still be on a private well.

Your water district

Who supplies Ronkonkoma’s water

EPA compliance

Federal violation record for Ronkonkoma’s suppliers

The annual report above lists what was found in the water. EPA’s compliance database records whether each supplier met its testing, treatment, and reporting obligations.

Compliance counts are EPA Safe Drinking Water Information System records pulled directly from EPA. Most violations are monitoring or reporting lapses, not unsafe water; health-based violations (a contaminant limit, disinfectant level, or treatment technique) are counted separately. A system listed for a ZIP code may serve only part of it.

What the numbers mean

Ronkonkoma is served largely by SCWA, with private wells mixed in toward its edges. Western and central Suffolk carry Long Island's signature groundwater story — trace 1,4-dioxane and PFAS from historic land use, plus nitrate loading from lawns and septic systems. SCWA treats for these at its wellfields, but a point-of-entry system gives you a second barrier and covers any private-well portion of the neighborhood.

What this means for filtration

Matching Ronkonkoma’s water to a system

For Ronkonkoma, the numbers point first to under-sink reverse osmosis and whole-house carbon filtration: dissolved contaminants close to their limits.

  • Recommended

    Under-Sink Reverse Osmosis

    Dissolved contaminants close to their limits

    Nitrate averaged 4.25 mg/L with samples up to 9.27 against a 10 mg/L limit — the closest number to its limit here. It passes straight through carbon; reverse osmosis is designed to reduce it at the tap. PFOA/PFOS reached 13 ng/L (ppt) in at least one sample — above New York's 10 ppt limit and at or above the 4.0 ppt federal MCL, with federal compliance due April 26, 2029. Whether an under-sink reverse osmosis model reduces PFOA or PFOS depends on that model's certification or performance data sheet. Perchlorate was detected up to 2.96 µg/L (limit 18). The supplier's 90th-percentile lead result was 0.00125 mg/L (1 ppb) against the 15 ppb action level. Lead enters water from a home's own service line and fixtures, so the system figure says little about any one house; a filter certified for lead (NSF/ANSI 53) or reverse osmosis at the kitchen tap reduces it at the point you drink.

    Explore Under-Sink Reverse Osmosis
  • Recommended

    Whole-House Carbon Filtration

    Solvent traces and chlorine in the supply

    Free chlorine averaged 0.98 mg/L at the entry point (limit 4), the residual that gives tap water its pool taste and dries skin and hair. Chlorination by-products (trihalomethanes) reached 9.32 µg/L in some samples against an 80 µg/L limit for the group; they are absorbed in the shower as well as drunk. Solvent traces were detected: Trichloroethene (TCE) up to 0.72 µg/L, Tetrachloroethene (PCE) up to 2.54 µg/L, 1,1,1-Trichloroethane up to 0.81 µg/L, cis-1,2-Dichloroethene up to 0.42 µg/L (limit 5 each). Whether a whole-house carbon model reduces those solvents is on that model's data sheet.

    Explore Whole-House Carbon Filtration
  • Worth considering

    Whole-House + Softener Combo

    Hardness 72.5 mg/L, about 4.2 grains per gallon

    At 72.5 mg/L (4.2 gpg) the water is moderately hard. A softener is a comfort choice here, not a necessity; some homes near the top of the 198 mg/L range will notice scale.

    Explore Whole-House + Softener Combo
  • Worth considering

    Private Well Treatment

    Iron up to 850 µg/L in some wells

    Iron peaked at 850 µg/L (average 88) against the 300 µg/L standard: orange staining on fixtures and laundry in the homes that get it. On a public supply this calls for an iron filter, the same oxidizing equipment used in a well package, only if you see the staining.